mirror of
https://git.FreeBSD.org/src.git
synced 2024-12-13 10:02:38 +00:00
4738f75303
which included commits to RCS files with non-trunk default branches.
1002 lines
25 KiB
Groff
1002 lines
25 KiB
Groff
.TH FLEX 1 "November 1993" "Version 2.4"
|
|
.SH NAME
|
|
flex \- fast lexical analyzer generator
|
|
.SH SYNOPSIS
|
|
.B flex
|
|
.B [\-bcdfhilnpstvwBFILTV78+ \-C[aefFmr] \-Pprefix \-Sskeleton]
|
|
.I [filename ...]
|
|
.SH DESCRIPTION
|
|
.I flex
|
|
is a tool for generating
|
|
.I scanners:
|
|
programs which recognized lexical patterns in text.
|
|
.I flex
|
|
reads
|
|
the given input files, or its standard input if no file names are given,
|
|
for a description of a scanner to generate. The description is in
|
|
the form of pairs
|
|
of regular expressions and C code, called
|
|
.I rules. flex
|
|
generates as output a C source file,
|
|
.B lex.yy.c,
|
|
which defines a routine
|
|
.B yylex().
|
|
This file is compiled and linked with the
|
|
.B \-lfl
|
|
library to produce an executable. When the executable is run,
|
|
it analyzes its input for occurrences
|
|
of the regular expressions. Whenever it finds one, it executes
|
|
the corresponding C code.
|
|
.PP
|
|
For full documentation, see
|
|
.B flexdoc(1).
|
|
This manual entry is intended for use as a quick reference.
|
|
.SH OPTIONS
|
|
.I flex
|
|
has the following options:
|
|
.TP
|
|
.B \-b
|
|
generate backing-up information to
|
|
.I lex.backup.
|
|
This is a list of scanner states which require backing up and the input
|
|
characters on which they do so. By adding rules one can remove
|
|
backing-up states. If all backing-up states are eliminated and
|
|
.B \-Cf
|
|
or
|
|
.B \-CF
|
|
is used, the generated scanner will run faster.
|
|
.TP
|
|
.B \-c
|
|
is a do-nothing, deprecated option included for POSIX compliance.
|
|
.IP
|
|
.B NOTE:
|
|
in previous releases of
|
|
.I flex
|
|
.B \-c
|
|
specified table-compression options. This functionality is
|
|
now given by the
|
|
.B \-C
|
|
flag. To ease the the impact of this change, when
|
|
.I flex
|
|
encounters
|
|
.B \-c,
|
|
it currently issues a warning message and assumes that
|
|
.B \-C
|
|
was desired instead. In the future this "promotion" of
|
|
.B \-c
|
|
to
|
|
.B \-C
|
|
will go away in the name of full POSIX compliance (unless
|
|
the POSIX meaning is removed first).
|
|
.TP
|
|
.B \-d
|
|
makes the generated scanner run in
|
|
.I debug
|
|
mode. Whenever a pattern is recognized and the global
|
|
.B yy_flex_debug
|
|
is non-zero (which is the default), the scanner will
|
|
write to
|
|
.I stderr
|
|
a line of the form:
|
|
.nf
|
|
|
|
--accepting rule at line 53 ("the matched text")
|
|
|
|
.fi
|
|
The line number refers to the location of the rule in the file
|
|
defining the scanner (i.e., the file that was fed to flex). Messages
|
|
are also generated when the scanner backs up, accepts the
|
|
default rule, reaches the end of its input buffer (or encounters
|
|
a NUL; the two look the same as far as the scanner's concerned),
|
|
or reaches an end-of-file.
|
|
.TP
|
|
.B \-f
|
|
specifies
|
|
.I fast scanner.
|
|
No table compression is done and stdio is bypassed.
|
|
The result is large but fast. This option is equivalent to
|
|
.B \-Cfr
|
|
(see below).
|
|
.TP
|
|
.B \-h
|
|
generates a "help" summary of
|
|
.I flex's
|
|
options to
|
|
.I stderr
|
|
and then exits.
|
|
.TP
|
|
.B \-i
|
|
instructs
|
|
.I flex
|
|
to generate a
|
|
.I case-insensitive
|
|
scanner. The case of letters given in the
|
|
.I flex
|
|
input patterns will
|
|
be ignored, and tokens in the input will be matched regardless of case. The
|
|
matched text given in
|
|
.I yytext
|
|
will have the preserved case (i.e., it will not be folded).
|
|
.TP
|
|
.B \-l
|
|
turns on maximum compatibility with the original AT&T lex implementation,
|
|
at a considerable performance cost. This option is incompatible with
|
|
.B \-+, \-f, \-F, \-Cf,
|
|
or
|
|
.B \-CF.
|
|
See
|
|
.I flexdoc(1)
|
|
for details.
|
|
.TP
|
|
.B \-n
|
|
is another do-nothing, deprecated option included only for
|
|
POSIX compliance.
|
|
.TP
|
|
.B \-p
|
|
generates a performance report to stderr. The report
|
|
consists of comments regarding features of the
|
|
.I flex
|
|
input file which will cause a loss of performance in the resulting scanner.
|
|
If you give the flag twice, you will also get comments regarding
|
|
features that lead to minor performance losses.
|
|
.TP
|
|
.B \-s
|
|
causes the
|
|
.I default rule
|
|
(that unmatched scanner input is echoed to
|
|
.I stdout)
|
|
to be suppressed. If the scanner encounters input that does not
|
|
match any of its rules, it aborts with an error.
|
|
.TP
|
|
.B \-t
|
|
instructs
|
|
.I flex
|
|
to write the scanner it generates to standard output instead
|
|
of
|
|
.B lex.yy.c.
|
|
.TP
|
|
.B \-v
|
|
specifies that
|
|
.I flex
|
|
should write to
|
|
.I stderr
|
|
a summary of statistics regarding the scanner it generates.
|
|
.TP
|
|
.B \-w
|
|
suppresses warning messages.
|
|
.TP
|
|
.B \-B
|
|
instructs
|
|
.I flex
|
|
to generate a
|
|
.I batch
|
|
scanner instead of an
|
|
.I interactive
|
|
scanner (see
|
|
.B \-I
|
|
below). See
|
|
.I flexdoc(1)
|
|
for details. Scanners using
|
|
.B \-Cf
|
|
or
|
|
.B \-CF
|
|
compression options automatically specify this option, too.
|
|
.TP
|
|
.B \-F
|
|
specifies that the
|
|
.ul
|
|
fast
|
|
scanner table representation should be used (and stdio bypassed).
|
|
This representation is about as fast as the full table representation
|
|
.B (-f),
|
|
and for some sets of patterns will be considerably smaller (and for
|
|
others, larger). It cannot be used with the
|
|
.B \-+
|
|
option. See
|
|
.B flexdoc(1)
|
|
for more details.
|
|
.IP
|
|
This option is equivalent to
|
|
.B \-CFr
|
|
(see below).
|
|
.TP
|
|
.B \-I
|
|
instructs
|
|
.I flex
|
|
to generate an
|
|
.I interactive
|
|
scanner, that is, a scanner which stops immediately rather than
|
|
looking ahead if it knows
|
|
that the currently scanned text cannot be part of a longer rule's match.
|
|
This is the opposite of
|
|
.I batch
|
|
scanners (see
|
|
.B \-B
|
|
above). See
|
|
.B flexdoc(1)
|
|
for details.
|
|
.IP
|
|
Note,
|
|
.B \-I
|
|
cannot be used in conjunction with
|
|
.I full
|
|
or
|
|
.I fast tables,
|
|
i.e., the
|
|
.B \-f, \-F, \-Cf,
|
|
or
|
|
.B \-CF
|
|
flags. For other table compression options,
|
|
.B \-I
|
|
is the default.
|
|
.TP
|
|
.B \-L
|
|
instructs
|
|
.I flex
|
|
not to generate
|
|
.B #line
|
|
directives in
|
|
.B lex.yy.c.
|
|
The default is to generate such directives so error
|
|
messages in the actions will be correctly
|
|
located with respect to the original
|
|
.I flex
|
|
input file, and not to
|
|
the fairly meaningless line numbers of
|
|
.B lex.yy.c.
|
|
.TP
|
|
.B \-T
|
|
makes
|
|
.I flex
|
|
run in
|
|
.I trace
|
|
mode. It will generate a lot of messages to
|
|
.I stderr
|
|
concerning
|
|
the form of the input and the resultant non-deterministic and deterministic
|
|
finite automata. This option is mostly for use in maintaining
|
|
.I flex.
|
|
.TP
|
|
.B \-V
|
|
prints the version number to
|
|
.I stderr
|
|
and exits.
|
|
.TP
|
|
.B \-7
|
|
instructs
|
|
.I flex
|
|
to generate a 7-bit scanner, which can save considerable table space,
|
|
especially when using
|
|
.B \-Cf
|
|
or
|
|
.B \-CF
|
|
(and, at most sites,
|
|
.B \-7
|
|
is on by default for these options. To see if this is the case, use the
|
|
.B -v
|
|
verbose flag and check the flag summary it reports).
|
|
.TP
|
|
.B \-8
|
|
instructs
|
|
.I flex
|
|
to generate an 8-bit scanner. This is the default except for the
|
|
.B \-Cf
|
|
and
|
|
.B \-CF
|
|
compression options, for which the default is site-dependent, and
|
|
can be checked by inspecting the flag summary generated by the
|
|
.B \-v
|
|
option.
|
|
.TP
|
|
.B \-+
|
|
specifies that you want flex to generate a C++
|
|
scanner class. See the section on Generating C++ Scanners in
|
|
.I flexdoc(1)
|
|
for details.
|
|
.TP
|
|
.B \-C[aefFmr]
|
|
controls the degree of table compression and scanner optimization.
|
|
.IP
|
|
.B \-Ca
|
|
trade off larger tables in the generated scanner for faster performance
|
|
because the elements of the tables are better aligned for memory access
|
|
and computation. This option can double the size of the tables used by
|
|
your scanner.
|
|
.IP
|
|
.B \-Ce
|
|
directs
|
|
.I flex
|
|
to construct
|
|
.I equivalence classes,
|
|
i.e., sets of characters
|
|
which have identical lexical properties.
|
|
Equivalence classes usually give
|
|
dramatic reductions in the final table/object file sizes (typically
|
|
a factor of 2-5) and are pretty cheap performance-wise (one array
|
|
look-up per character scanned).
|
|
.IP
|
|
.B \-Cf
|
|
specifies that the
|
|
.I full
|
|
scanner tables should be generated -
|
|
.I flex
|
|
should not compress the
|
|
tables by taking advantages of similar transition functions for
|
|
different states.
|
|
.IP
|
|
.B \-CF
|
|
specifies that the alternate fast scanner representation (described in
|
|
.B flexdoc(1))
|
|
should be used. This option cannot be used with
|
|
.B \-+.
|
|
.IP
|
|
.B \-Cm
|
|
directs
|
|
.I flex
|
|
to construct
|
|
.I meta-equivalence classes,
|
|
which are sets of equivalence classes (or characters, if equivalence
|
|
classes are not being used) that are commonly used together. Meta-equivalence
|
|
classes are often a big win when using compressed tables, but they
|
|
have a moderate performance impact (one or two "if" tests and one
|
|
array look-up per character scanned).
|
|
.IP
|
|
.B \-Cr
|
|
causes the generated scanner to
|
|
.I bypass
|
|
using stdio for input. In general this option results in a minor
|
|
performance gain only worthwhile if used in conjunction with
|
|
.B \-Cf
|
|
or
|
|
.B \-CF.
|
|
It can cause surprising behavior if you use stdio yourself to
|
|
read from
|
|
.I yyin
|
|
prior to calling the scanner.
|
|
.IP
|
|
A lone
|
|
.B \-C
|
|
specifies that the scanner tables should be compressed but neither
|
|
equivalence classes nor meta-equivalence classes should be used.
|
|
.IP
|
|
The options
|
|
.B \-Cf
|
|
or
|
|
.B \-CF
|
|
and
|
|
.B \-Cm
|
|
do not make sense together - there is no opportunity for meta-equivalence
|
|
classes if the table is not being compressed. Otherwise the options
|
|
may be freely mixed.
|
|
.IP
|
|
The default setting is
|
|
.B \-Cem,
|
|
which specifies that
|
|
.I flex
|
|
should generate equivalence classes
|
|
and meta-equivalence classes. This setting provides the highest
|
|
degree of table compression. You can trade off
|
|
faster-executing scanners at the cost of larger tables with
|
|
the following generally being true:
|
|
.nf
|
|
|
|
slowest & smallest
|
|
-Cem
|
|
-Cm
|
|
-Ce
|
|
-C
|
|
-C{f,F}e
|
|
-C{f,F}
|
|
-C{f,F}a
|
|
fastest & largest
|
|
|
|
.fi
|
|
.IP
|
|
.B \-C
|
|
options are cumulative.
|
|
.TP
|
|
.B \-Pprefix
|
|
changes the default
|
|
.I "yy"
|
|
prefix used by
|
|
.I flex
|
|
to be
|
|
.I prefix
|
|
instead. See
|
|
.I flexdoc(1)
|
|
for a description of all the global variables and file names that
|
|
this affects.
|
|
.TP
|
|
.B \-Sskeleton_file
|
|
overrides the default skeleton file from which
|
|
.I flex
|
|
constructs its scanners. You'll never need this option unless you are doing
|
|
.I flex
|
|
maintenance or development.
|
|
.SH SUMMARY OF FLEX REGULAR EXPRESSIONS
|
|
The patterns in the input are written using an extended set of regular
|
|
expressions. These are:
|
|
.nf
|
|
|
|
x match the character 'x'
|
|
. any character except newline
|
|
[xyz] a "character class"; in this case, the pattern
|
|
matches either an 'x', a 'y', or a 'z'
|
|
[abj-oZ] a "character class" with a range in it; matches
|
|
an 'a', a 'b', any letter from 'j' through 'o',
|
|
or a 'Z'
|
|
[^A-Z] a "negated character class", i.e., any character
|
|
but those in the class. In this case, any
|
|
character EXCEPT an uppercase letter.
|
|
[^A-Z\\n] any character EXCEPT an uppercase letter or
|
|
a newline
|
|
r* zero or more r's, where r is any regular expression
|
|
r+ one or more r's
|
|
r? zero or one r's (that is, "an optional r")
|
|
r{2,5} anywhere from two to five r's
|
|
r{2,} two or more r's
|
|
r{4} exactly 4 r's
|
|
{name} the expansion of the "name" definition
|
|
(see above)
|
|
"[xyz]\\"foo"
|
|
the literal string: [xyz]"foo
|
|
\\X if X is an 'a', 'b', 'f', 'n', 'r', 't', or 'v',
|
|
then the ANSI-C interpretation of \\x.
|
|
Otherwise, a literal 'X' (used to escape
|
|
operators such as '*')
|
|
\\123 the character with octal value 123
|
|
\\x2a the character with hexadecimal value 2a
|
|
(r) match an r; parentheses are used to override
|
|
precedence (see below)
|
|
|
|
|
|
rs the regular expression r followed by the
|
|
regular expression s; called "concatenation"
|
|
|
|
|
|
r|s either an r or an s
|
|
|
|
|
|
r/s an r but only if it is followed by an s. The
|
|
s is not part of the matched text. This type
|
|
of pattern is called as "trailing context".
|
|
^r an r, but only at the beginning of a line
|
|
r$ an r, but only at the end of a line. Equivalent
|
|
to "r/\\n".
|
|
|
|
|
|
<s>r an r, but only in start condition s (see
|
|
below for discussion of start conditions)
|
|
<s1,s2,s3>r
|
|
same, but in any of start conditions s1,
|
|
s2, or s3
|
|
<*>r an r in any start condition, even an exclusive one.
|
|
|
|
|
|
<<EOF>> an end-of-file
|
|
<s1,s2><<EOF>>
|
|
an end-of-file when in start condition s1 or s2
|
|
|
|
.fi
|
|
The regular expressions listed above are grouped according to
|
|
precedence, from highest precedence at the top to lowest at the bottom.
|
|
Those grouped together have equal precedence.
|
|
.PP
|
|
Some notes on patterns:
|
|
.IP -
|
|
Negated character classes
|
|
.I match newlines
|
|
unless "\\n" (or an equivalent escape sequence) is one of the
|
|
characters explicitly present in the negated character class
|
|
(e.g., "[^A-Z\\n]").
|
|
.IP -
|
|
A rule can have at most one instance of trailing context (the '/' operator
|
|
or the '$' operator). The start condition, '^', and "<<EOF>>" patterns
|
|
can only occur at the beginning of a pattern, and, as well as with '/' and '$',
|
|
cannot be grouped inside parentheses. The following are all illegal:
|
|
.nf
|
|
|
|
foo/bar$
|
|
foo|(bar$)
|
|
foo|^bar
|
|
<sc1>foo<sc2>bar
|
|
|
|
.fi
|
|
.SH SUMMARY OF SPECIAL ACTIONS
|
|
In addition to arbitrary C code, the following can appear in actions:
|
|
.IP -
|
|
.B ECHO
|
|
copies yytext to the scanner's output.
|
|
.IP -
|
|
.B BEGIN
|
|
followed by the name of a start condition places the scanner in the
|
|
corresponding start condition.
|
|
.IP -
|
|
.B REJECT
|
|
directs the scanner to proceed on to the "second best" rule which matched the
|
|
input (or a prefix of the input).
|
|
.B yytext
|
|
and
|
|
.B yyleng
|
|
are set up appropriately. Note that
|
|
.B REJECT
|
|
is a particularly expensive feature in terms scanner performance;
|
|
if it is used in
|
|
.I any
|
|
of the scanner's actions it will slow down
|
|
.I all
|
|
of the scanner's matching. Furthermore,
|
|
.B REJECT
|
|
cannot be used with the
|
|
.B \-f
|
|
or
|
|
.B \-F
|
|
options.
|
|
.IP
|
|
Note also that unlike the other special actions,
|
|
.B REJECT
|
|
is a
|
|
.I branch;
|
|
code immediately following it in the action will
|
|
.I not
|
|
be executed.
|
|
.IP -
|
|
.B yymore()
|
|
tells the scanner that the next time it matches a rule, the corresponding
|
|
token should be
|
|
.I appended
|
|
onto the current value of
|
|
.B yytext
|
|
rather than replacing it.
|
|
.IP -
|
|
.B yyless(n)
|
|
returns all but the first
|
|
.I n
|
|
characters of the current token back to the input stream, where they
|
|
will be rescanned when the scanner looks for the next match.
|
|
.B yytext
|
|
and
|
|
.B yyleng
|
|
are adjusted appropriately (e.g.,
|
|
.B yyleng
|
|
will now be equal to
|
|
.I n
|
|
).
|
|
.IP -
|
|
.B unput(c)
|
|
puts the character
|
|
.I c
|
|
back onto the input stream. It will be the next character scanned.
|
|
.IP -
|
|
.B input()
|
|
reads the next character from the input stream (this routine is called
|
|
.B yyinput()
|
|
if the scanner is compiled using
|
|
.B C++).
|
|
.IP -
|
|
.B yyterminate()
|
|
can be used in lieu of a return statement in an action. It terminates
|
|
the scanner and returns a 0 to the scanner's caller, indicating "all done".
|
|
.IP
|
|
By default,
|
|
.B yyterminate()
|
|
is also called when an end-of-file is encountered. It is a macro and
|
|
may be redefined.
|
|
.IP -
|
|
.B YY_NEW_FILE
|
|
is an action available only in <<EOF>> rules. It means "Okay, I've
|
|
set up a new input file, continue scanning". It is no longer required;
|
|
you can just assign
|
|
.I yyin
|
|
to point to a new file in the <<EOF>> action.
|
|
.IP -
|
|
.B yy_create_buffer( file, size )
|
|
takes a
|
|
.I FILE
|
|
pointer and an integer
|
|
.I size.
|
|
It returns a YY_BUFFER_STATE
|
|
handle to a new input buffer large enough to accomodate
|
|
.I size
|
|
characters and associated with the given file. When in doubt, use
|
|
.B YY_BUF_SIZE
|
|
for the size.
|
|
.IP -
|
|
.B yy_switch_to_buffer( new_buffer )
|
|
switches the scanner's processing to scan for tokens from
|
|
the given buffer, which must be a YY_BUFFER_STATE.
|
|
.IP -
|
|
.B yy_delete_buffer( buffer )
|
|
deletes the given buffer.
|
|
.SH VALUES AVAILABLE TO THE USER
|
|
.IP -
|
|
.B char *yytext
|
|
holds the text of the current token. It may be modified but not lengthened
|
|
(you cannot append characters to the end). Modifying the last character
|
|
may affect the activity of rules anchored using '^' during the next scan;
|
|
see
|
|
.B flexdoc(1)
|
|
for details.
|
|
.IP
|
|
If the special directive
|
|
.B %array
|
|
appears in the first section of the scanner description, then
|
|
.B yytext
|
|
is instead declared
|
|
.B char yytext[YYLMAX],
|
|
where
|
|
.B YYLMAX
|
|
is a macro definition that you can redefine in the first section
|
|
if you don't like the default value (generally 8KB). Using
|
|
.B %array
|
|
results in somewhat slower scanners, but the value of
|
|
.B yytext
|
|
becomes immune to calls to
|
|
.I input()
|
|
and
|
|
.I unput(),
|
|
which potentially destroy its value when
|
|
.B yytext
|
|
is a character pointer. The opposite of
|
|
.B %array
|
|
is
|
|
.B %pointer,
|
|
which is the default.
|
|
.IP
|
|
You cannot use
|
|
.B %array
|
|
when generating C++ scanner classes
|
|
(the
|
|
.B \-+
|
|
flag).
|
|
.IP -
|
|
.B int yyleng
|
|
holds the length of the current token.
|
|
.IP -
|
|
.B FILE *yyin
|
|
is the file which by default
|
|
.I flex
|
|
reads from. It may be redefined but doing so only makes sense before
|
|
scanning begins or after an EOF has been encountered. Changing it in
|
|
the midst of scanning will have unexpected results since
|
|
.I flex
|
|
buffers its input; use
|
|
.B yyrestart()
|
|
instead.
|
|
Once scanning terminates because an end-of-file
|
|
has been seen,
|
|
.B
|
|
you can assign
|
|
.I yyin
|
|
at the new input file and then call the scanner again to continue scanning.
|
|
.IP -
|
|
.B void yyrestart( FILE *new_file )
|
|
may be called to point
|
|
.I yyin
|
|
at the new input file. The switch-over to the new file is immediate
|
|
(any previously buffered-up input is lost). Note that calling
|
|
.B yyrestart()
|
|
with
|
|
.I yyin
|
|
as an argument thus throws away the current input buffer and continues
|
|
scanning the same input file.
|
|
.IP -
|
|
.B FILE *yyout
|
|
is the file to which
|
|
.B ECHO
|
|
actions are done. It can be reassigned by the user.
|
|
.IP -
|
|
.B YY_CURRENT_BUFFER
|
|
returns a
|
|
.B YY_BUFFER_STATE
|
|
handle to the current buffer.
|
|
.IP -
|
|
.B YY_START
|
|
returns an integer value corresponding to the current start
|
|
condition. You can subsequently use this value with
|
|
.B BEGIN
|
|
to return to that start condition.
|
|
.SH MACROS AND FUNCTIONS YOU CAN REDEFINE
|
|
.IP -
|
|
.B YY_DECL
|
|
controls how the scanning routine is declared.
|
|
By default, it is "int yylex()", or, if prototypes are being
|
|
used, "int yylex(void)". This definition may be changed by redefining
|
|
the "YY_DECL" macro. Note that
|
|
if you give arguments to the scanning routine using a
|
|
K&R-style/non-prototyped function declaration, you must terminate
|
|
the definition with a semi-colon (;).
|
|
.IP -
|
|
The nature of how the scanner
|
|
gets its input can be controlled by redefining the
|
|
.B YY_INPUT
|
|
macro.
|
|
YY_INPUT's calling sequence is "YY_INPUT(buf,result,max_size)". Its
|
|
action is to place up to
|
|
.I max_size
|
|
characters in the character array
|
|
.I buf
|
|
and return in the integer variable
|
|
.I result
|
|
either the
|
|
number of characters read or the constant YY_NULL (0 on Unix systems)
|
|
to indicate EOF. The default YY_INPUT reads from the
|
|
global file-pointer "yyin".
|
|
A sample redefinition of YY_INPUT (in the definitions
|
|
section of the input file):
|
|
.nf
|
|
|
|
%{
|
|
#undef YY_INPUT
|
|
#define YY_INPUT(buf,result,max_size) \\
|
|
{ \\
|
|
int c = getchar(); \\
|
|
result = (c == EOF) ? YY_NULL : (buf[0] = c, 1); \\
|
|
}
|
|
%}
|
|
|
|
.fi
|
|
.IP -
|
|
When the scanner receives an end-of-file indication from YY_INPUT,
|
|
it then checks the function
|
|
.B yywrap()
|
|
function. If
|
|
.B yywrap()
|
|
returns false (zero), then it is assumed that the
|
|
function has gone ahead and set up
|
|
.I yyin
|
|
to point to another input file, and scanning continues. If it returns
|
|
true (non-zero), then the scanner terminates, returning 0 to its
|
|
caller.
|
|
.IP
|
|
The default
|
|
.B yywrap()
|
|
always returns 1.
|
|
.IP -
|
|
YY_USER_ACTION
|
|
can be redefined to provide an action
|
|
which is always executed prior to the matched rule's action.
|
|
.IP -
|
|
The macro
|
|
.B YY_USER_INIT
|
|
may be redefined to provide an action which is always executed before
|
|
the first scan.
|
|
.IP -
|
|
In the generated scanner, the actions are all gathered in one large
|
|
switch statement and separated using
|
|
.B YY_BREAK,
|
|
which may be redefined. By default, it is simply a "break", to separate
|
|
each rule's action from the following rule's.
|
|
.SH FILES
|
|
.TP
|
|
.B \-lfl
|
|
library with which to link scanners to obtain the default versions
|
|
of
|
|
.I yywrap()
|
|
and/or
|
|
.I main().
|
|
.TP
|
|
.I lex.yy.c
|
|
generated scanner (called
|
|
.I lexyy.c
|
|
on some systems).
|
|
.TP
|
|
.I lex.yy.cc
|
|
generated C++ scanner class, when using
|
|
.B -+.
|
|
.TP
|
|
.I <FlexLexer.h>
|
|
header file defining the C++ scanner base class,
|
|
.B FlexLexer,
|
|
and its derived class,
|
|
.B yyFlexLexer.
|
|
.TP
|
|
.I flex.skl
|
|
skeleton scanner. This file is only used when building flex, not when
|
|
flex executes.
|
|
.TP
|
|
.I lex.backup
|
|
backing-up information for
|
|
.B \-b
|
|
flag (called
|
|
.I lex.bck
|
|
on some systems).
|
|
.SH "SEE ALSO"
|
|
.PP
|
|
flexdoc(1), lex(1), yacc(1), sed(1), awk(1).
|
|
.PP
|
|
M. E. Lesk and E. Schmidt,
|
|
.I LEX \- Lexical Analyzer Generator
|
|
.SH DIAGNOSTICS
|
|
.PP
|
|
.I reject_used_but_not_detected undefined
|
|
or
|
|
.PP
|
|
.I yymore_used_but_not_detected undefined -
|
|
These errors can occur at compile time. They indicate that the
|
|
scanner uses
|
|
.B REJECT
|
|
or
|
|
.B yymore()
|
|
but that
|
|
.I flex
|
|
failed to notice the fact, meaning that
|
|
.I flex
|
|
scanned the first two sections looking for occurrences of these actions
|
|
and failed to find any, but somehow you snuck some in (via a #include
|
|
file, for example). Make an explicit reference to the action in your
|
|
.I flex
|
|
input file. (Note that previously
|
|
.I flex
|
|
supported a
|
|
.B %used/%unused
|
|
mechanism for dealing with this problem; this feature is still supported
|
|
but now deprecated, and will go away soon unless the author hears from
|
|
people who can argue compellingly that they need it.)
|
|
.PP
|
|
.I flex scanner jammed -
|
|
a scanner compiled with
|
|
.B \-s
|
|
has encountered an input string which wasn't matched by
|
|
any of its rules.
|
|
.PP
|
|
.I warning, rule cannot be matched
|
|
indicates that the given rule
|
|
cannot be matched because it follows other rules that will
|
|
always match the same text as it. See
|
|
.I flexdoc(1)
|
|
for an example.
|
|
.PP
|
|
.I warning,
|
|
.B \-s
|
|
.I
|
|
option given but default rule can be matched
|
|
means that it is possible (perhaps only in a particular start condition)
|
|
that the default rule (match any single character) is the only one
|
|
that will match a particular input. Since
|
|
.PP
|
|
.I scanner input buffer overflowed -
|
|
a scanner rule matched more text than the available dynamic memory.
|
|
.PP
|
|
.I token too large, exceeds YYLMAX -
|
|
your scanner uses
|
|
.B %array
|
|
and one of its rules matched a string longer than the
|
|
.B YYLMAX
|
|
constant (8K bytes by default). You can increase the value by
|
|
#define'ing
|
|
.B YYLMAX
|
|
in the definitions section of your
|
|
.I flex
|
|
input.
|
|
.PP
|
|
.I scanner requires \-8 flag to
|
|
.I use the character 'x' -
|
|
Your scanner specification includes recognizing the 8-bit character
|
|
.I 'x'
|
|
and you did not specify the \-8 flag, and your scanner defaulted to 7-bit
|
|
because you used the
|
|
.B \-Cf
|
|
or
|
|
.B \-CF
|
|
table compression options.
|
|
.PP
|
|
.I flex scanner push-back overflow -
|
|
you used
|
|
.B unput()
|
|
to push back so much text that the scanner's buffer could not hold
|
|
both the pushed-back text and the current token in
|
|
.B yytext.
|
|
Ideally the scanner should dynamically resize the buffer in this case, but at
|
|
present it does not.
|
|
.PP
|
|
.I
|
|
input buffer overflow, can't enlarge buffer because scanner uses REJECT -
|
|
the scanner was working on matching an extremely large token and needed
|
|
to expand the input buffer. This doesn't work with scanners that use
|
|
.B
|
|
REJECT.
|
|
.PP
|
|
.I
|
|
fatal flex scanner internal error--end of buffer missed -
|
|
This can occur in an scanner which is reentered after a long-jump
|
|
has jumped out (or over) the scanner's activation frame. Before
|
|
reentering the scanner, use:
|
|
.nf
|
|
|
|
yyrestart( yyin );
|
|
|
|
.fi
|
|
or use C++ scanner classes (the
|
|
.B \-+
|
|
option), which are fully reentrant.
|
|
.SH AUTHOR
|
|
Vern Paxson, with the help of many ideas and much inspiration from
|
|
Van Jacobson. Original version by Jef Poskanzer.
|
|
.PP
|
|
See flexdoc(1) for additional credits and the address to send comments to.
|
|
.SH DEFICIENCIES / BUGS
|
|
.PP
|
|
Some trailing context
|
|
patterns cannot be properly matched and generate
|
|
warning messages ("dangerous trailing context"). These are
|
|
patterns where the ending of the
|
|
first part of the rule matches the beginning of the second
|
|
part, such as "zx*/xy*", where the 'x*' matches the 'x' at
|
|
the beginning of the trailing context. (Note that the POSIX draft
|
|
states that the text matched by such patterns is undefined.)
|
|
.PP
|
|
For some trailing context rules, parts which are actually fixed-length are
|
|
not recognized as such, leading to the abovementioned performance loss.
|
|
In particular, parts using '|' or {n} (such as "foo{3}") are always
|
|
considered variable-length.
|
|
.PP
|
|
Combining trailing context with the special '|' action can result in
|
|
.I fixed
|
|
trailing context being turned into the more expensive
|
|
.I variable
|
|
trailing context. For example, in the following:
|
|
.nf
|
|
|
|
%%
|
|
abc |
|
|
xyz/def
|
|
|
|
.fi
|
|
.PP
|
|
Use of
|
|
.B unput()
|
|
or
|
|
.B input()
|
|
invalidates yytext and yyleng, unless the
|
|
.B %array
|
|
directive
|
|
or the
|
|
.B \-l
|
|
option has been used.
|
|
.PP
|
|
Use of unput() to push back more text than was matched can
|
|
result in the pushed-back text matching a beginning-of-line ('^')
|
|
rule even though it didn't come at the beginning of the line
|
|
(though this is rare!).
|
|
.PP
|
|
Pattern-matching of NUL's is substantially slower than matching other
|
|
characters.
|
|
.PP
|
|
Dynamic resizing of the input buffer is slow, as it entails rescanning
|
|
all the text matched so far by the current (generally huge) token.
|
|
.PP
|
|
.I flex
|
|
does not generate correct #line directives for code internal
|
|
to the scanner; thus, bugs in
|
|
.I flex.skl
|
|
yield bogus line numbers.
|
|
.PP
|
|
Due to both buffering of input and read-ahead, you cannot intermix
|
|
calls to <stdio.h> routines, such as, for example,
|
|
.B getchar(),
|
|
with
|
|
.I flex
|
|
rules and expect it to work. Call
|
|
.B input()
|
|
instead.
|
|
.PP
|
|
The total table entries listed by the
|
|
.B \-v
|
|
flag excludes the number of table entries needed to determine
|
|
what rule has been matched. The number of entries is equal
|
|
to the number of DFA states if the scanner does not use
|
|
.B REJECT,
|
|
and somewhat greater than the number of states if it does.
|
|
.PP
|
|
.B REJECT
|
|
cannot be used with the
|
|
.B \-f
|
|
or
|
|
.B \-F
|
|
options.
|
|
.PP
|
|
The
|
|
.I flex
|
|
internal algorithms need documentation.
|