mirror of
https://git.FreeBSD.org/ports.git
synced 2024-11-24 00:45:52 +00:00
APC smart UPS monitoring daemon.
PR: 4662 Submitted by: Daniel Baker <dbaker@neosoft.com> and myself
This commit is contained in:
parent
6cbfa7badc
commit
415268cc40
Notes:
svn2git
2021-03-31 03:12:20 +00:00
svn path=/head/; revision=9929
30
sysutils/upsd/Makefile
Normal file
30
sysutils/upsd/Makefile
Normal file
@ -0,0 +1,30 @@
|
||||
# New ports collection makefile for: upsd
|
||||
# Version required: 2.0.1.6
|
||||
# Date created: 11 Jul 1996
|
||||
# Whom: alexis
|
||||
#
|
||||
# $Id$
|
||||
#
|
||||
|
||||
DISTNAME= upsd-2.0.1.6
|
||||
PKGNAME= upsd-2.0
|
||||
CATEGORIES= sysutils
|
||||
MASTER_SITES= ftp://www.ww.net/pub/wildwind/upsd/ \
|
||||
http://www.cre8tivegroup.com/ \
|
||||
ftp://ftp.sw.ru/pub/unix/upsd/
|
||||
|
||||
MAINTAINER= alexis@ww.net
|
||||
|
||||
WRKSRC= ${WRKDIR}/upsd-2.0
|
||||
|
||||
pre-build:
|
||||
@${MV} ${WRKSRC}/config.h ${WRKSRC}/config.h.orig
|
||||
@sed -e "s!@prefix@!${PREFIX}!g" ${WRKSRC}/config.h.orig > ${WRKSRC}/config.h
|
||||
|
||||
post-install:
|
||||
if [ ! -f ${PREFIX}/etc/upsd.conf ] ; then \
|
||||
${INSTALL} -c -o ${BINOWN} -g ${BINGRP} -m 644 \
|
||||
${FILESDIR}/upsd.conf ${PREFIX}/etc/upsd.conf; \
|
||||
fi
|
||||
|
||||
.include <bsd.port.mk>
|
1
sysutils/upsd/distinfo
Normal file
1
sysutils/upsd/distinfo
Normal file
@ -0,0 +1 @@
|
||||
MD5 (upsd-2.0.1.6.tar.gz) = 98e46c6f86a87cb441931e1e4bf355c5
|
12
sysutils/upsd/files/patch-aa
Normal file
12
sysutils/upsd/files/patch-aa
Normal file
@ -0,0 +1,12 @@
|
||||
--- Makefile.orig Mon Feb 23 17:32:56 1998
|
||||
+++ Makefile Mon Feb 23 17:33:50 1998
|
||||
@@ -8,8 +8,7 @@
|
||||
|
||||
PROG= upsd
|
||||
|
||||
-BINDIR= /usr/local/sbin
|
||||
-MANDIR= /usr/local/share/man
|
||||
+BINDIR= ${PREFIX}/sbin
|
||||
NOMAN= noway
|
||||
|
||||
#DEBUG= -g -DDEBUG
|
11
sysutils/upsd/files/patch-ab
Normal file
11
sysutils/upsd/files/patch-ab
Normal file
@ -0,0 +1,11 @@
|
||||
--- config.h.orig Mon Feb 23 17:50:34 1998
|
||||
+++ config.h Mon Feb 23 17:50:49 1998
|
||||
@@ -8,7 +8,7 @@
|
||||
*/
|
||||
|
||||
#ifndef DEBUG
|
||||
-#define _PATH_UPSD_CONF "/etc/upsd.conf"
|
||||
+#define _PATH_UPSD_CONF "@prefix@/upsd.conf"
|
||||
#define _PATH_UPSD_PID "/var/run/upsd.pid"
|
||||
#else
|
||||
#define _PATH_UPSD_CONF "sample/upsd.conf"
|
100
sysutils/upsd/files/upsd.conf
Normal file
100
sysutils/upsd/files/upsd.conf
Normal file
@ -0,0 +1,100 @@
|
||||
# $Id: upsd.conf,v 2.0 1996/01/28 11:50:37 alexis Exp $
|
||||
#
|
||||
# UPS Daemon
|
||||
# The Wild Wind Communications, 1995, 1996
|
||||
#
|
||||
# See file LICENSE for the distribution terms of this software.
|
||||
#
|
||||
|
||||
ups "smart-ups" (230) proto "apc-smart" {
|
||||
device "/dev/cuaa0"
|
||||
speed 2400
|
||||
read-timeout 2
|
||||
write-block-size 1
|
||||
write-block-delay 50
|
||||
queue-size 64
|
||||
}
|
||||
|
||||
every 5 { # check events every 5 seconds
|
||||
nop
|
||||
}
|
||||
|
||||
on "initialize" != "SM" {
|
||||
poll "initialize"
|
||||
after 60 every 60 {
|
||||
log emerg "Cannot put the UPS into smart mode!"
|
||||
}
|
||||
}
|
||||
|
||||
every 600 {
|
||||
tune "high-transfer-point" 264
|
||||
tune "low-transfer-point" 196
|
||||
tune "line-alarm" "0"
|
||||
tune "line-sensitivity" "L"
|
||||
tune "low-batteries-duration" 2
|
||||
tune "nominal-voltage" 220
|
||||
tune "shutdown-delay" 20
|
||||
tune "wakeup-batteries-capacity" 25
|
||||
tune "wakeup-delay" 0
|
||||
# tune "batteries-replaced" "01/01/77"
|
||||
# tune "label" "WildWind"
|
||||
}
|
||||
|
||||
every 300 { # poll the UPS
|
||||
poll "last-test"
|
||||
# poll "light-test"
|
||||
poll "line-frequency"
|
||||
poll "line-maxvac"
|
||||
poll "line-minvac"
|
||||
poll "line-voltage"
|
||||
poll "load"
|
||||
poll "recharge"
|
||||
poll "temperature"
|
||||
poll "vdc"
|
||||
poll "voltage"
|
||||
|
||||
log notice "last test: %last-test%, light test: %light-test%"
|
||||
log notice "frequency: %line-frequency%, maxvac: %line-maxvac%, minvac: %line-minvac%, voltage: %line-voltage%"
|
||||
log notice "load: %load%, recharge: %recharge%, temp: %temperature%, vdc: %vdc%, output voltage: %voltage%"
|
||||
|
||||
on "load" > 95 {
|
||||
log alert "UPS load is too high: %load%"
|
||||
}
|
||||
}
|
||||
|
||||
on "line-fail" {
|
||||
log emerg "*** ALERT! Source power line failed, save your work! ***"
|
||||
}
|
||||
|
||||
on "line-fail" after 30 {
|
||||
log emerg "*** ALERT! System shutdown in 30 seconds, LOGOUT NOW! ***"
|
||||
}
|
||||
|
||||
on "line-restore" {
|
||||
log emerg "Source power line restored, you may continue your work."
|
||||
}
|
||||
|
||||
on "line-fail" after 60 {
|
||||
log emerg "*** ALERT! THE SYSTEM IS SHUTTING DOWN! ***"
|
||||
|
||||
poll "shutdown"
|
||||
poll "shutdown"
|
||||
poll "power-test"
|
||||
poll "power-test"
|
||||
poll "shutdown"
|
||||
poll "shutdown"
|
||||
|
||||
sleep 2
|
||||
|
||||
exec "/sbin/halt &"
|
||||
|
||||
poll "power-test"
|
||||
poll "shutdown"
|
||||
poll "power-test"
|
||||
poll "shutdown"
|
||||
poll "power-test"
|
||||
poll "shutdown"
|
||||
poll "power-test"
|
||||
|
||||
sleep 1000 # let us wait peacefully
|
||||
}
|
1
sysutils/upsd/pkg-comment
Normal file
1
sysutils/upsd/pkg-comment
Normal file
@ -0,0 +1 @@
|
||||
APC Smart UPS Monitoring Daemon
|
3
sysutils/upsd/pkg-descr
Normal file
3
sysutils/upsd/pkg-descr
Normal file
@ -0,0 +1,3 @@
|
||||
upsd is a daemon with flexible configuration which lets you to
|
||||
shutdown your system properly when source power line fails and
|
||||
measure its frequency, voltage etc
|
2
sysutils/upsd/pkg-plist
Normal file
2
sysutils/upsd/pkg-plist
Normal file
@ -0,0 +1,2 @@
|
||||
etc/upsd.conf
|
||||
sbin/upsd
|
Loading…
Reference in New Issue
Block a user