1
0
mirror of https://git.FreeBSD.org/ports.git synced 2024-10-29 21:39:24 +00:00
freebsd-ports/sysutils/libretto-config/files/patch-ad
Seiichirou Hiraoka d99d5adf37 PR: ports/8934
Submitted by:	shige@kuis.kyoto-u.ac.jp
Initial Import libretto-config.
The utility program to configure the BIOS setting
of the mini notebook computer, Toshiba Libretto.
1998-12-05 05:35:47 +00:00

102 lines
2.9 KiB
Plaintext

--- libapm-e.man.orig Fri Jun 19 12:02:48 1998
+++ libapm-e.man Thu Nov 26 12:38:56 1998
@@ -1,73 +1,73 @@
.\" Written Tue May 12 19:30:00 1998 by ISHIOKA Takashi
.\" (ishioka@ppp01.infopepper.or.jp )
-.TH libapm l "" "TOSHIBA Libretto only" ""
+.TH libretto-config 8 "" "TOSHIBA Libretto only" ""
.SH NAME
-libapm \- TOSHIBA Libretto BIOS Setup Program
+libretto-config \- TOSHIBA Libretto BIOS Setup Program
.SH SYNOPSIS
-.B libapm
-{\-v,\-\-Version}
-{\-h,\-\-Help}
+.B libretto-config
+{\-v}
+{\-h}
-.B libapm
-{\-P,\-\-PowerUp (boot,hibernation)}
-{\-T,\-\-StandbyTime (0,5,10,15,30,45,60)}
-{\-a,\-\-AutoOff (disable,10,20,30,40,50,60)}
-{\-S,\-\-PanelSwitch (disable,enable)}
-{\-A,\-\-PowerOn (disable,<time>)}
-{\-L,\-\-LcdPower (0,1,2,3)}
-{\-V,\-\-Volume (0,1,2,3)}
-{\-O,\-\-Off (suspend|hibernation)}
+.B libretto-config
+{\-P (boot,hibernation)}
+{\-T (0,5,10,15,30,45,60)}
+{\-a (disable,10,20,30,40,50,60)}
+{\-S (disable,enable)}
+{\-A (disable,<time>)}
+{\-L (0,1,2,3)}
+{\-V (0,1,2,3)}
+{\-O (suspend|hibernation)}
.SH DESCRIPTION
-.B libapm
+.B libretto-config
configures the setting of Toshiba Libretto.
Changes are done immediately and rebooting is not neccesary.
.SH OPTIONS
.TP
-.B \-P,\-\-PowerUp (boot,hibernation)
+.B \-P (boot,hibernation)
sets the Hibernation function.
If hibernation is specified, the hibernation function is enabled.
If boot is specified, it is disabled.
.TP
-.B \-T,\-\-StandbyTime (0,5,10,15,30,45,60)
+.B \-T (0,5,10,15,30,45,60)
sets the Standby time.
If the Stanby time is specified, the power is not cut after hibernation
for that time in order to resume quickly from hibernation.
You can select the time from 0, 5, 10, 15, 30, 45, 60 minutes.
This function is valid if the hibernation function is enabled.
.TP
-.B \-a,\-\-AutoOff (disable,10,20,30,40,50,60)
+.B \-a (disable,10,20,30,40,50,60)
sets the time to the Auto Power Off.
You can select the time from disable, 10, 20, 30, 40, 50, 60 minutes.
This function is valid if the hibernation function is enabled.
.TP
-.B \-S,\-\-PanelSwitch (disable,enable)
+.B \-S (disable,enable)
sets the Panel Switch funtion. If enabled, hibernation is done by
closing the panel and vice versa.
This function is valid if the hibernation function is enabled.
.TP
-.B \-A,\-\-PowerOn (disable,<time>)
+.B \-A (disable,<time>)
sets the Power On timer.
The format of the <time> is hh:mm. If time is specified, power is
automatically turned on at the time.
.TP
-.B \-L,\-\-LcdPower (0,1,2,3)
+.B \-L (0,1,2,3)
sets the brightness of the LCD.
0 is the darkest and 3 is the brightest.
.TP
-.B \-V,\-\-Volume (0,1,2,3)
+.B \-V (0,1,2,3)
sets the volume of beep sound.
0 is off, 1 is minimum and 3 is maximum.
.TP
-.B \-O,\-\-Off (suspend|hibernation)
+.B \-O (suspend|hibernation)
sets the suspend/hibernation mode. (100CT Only)
.TP
-.B \-v,\-\-Version
+.B \-v
displays the version of this program.
.TP
-.B \-h,\-\-Help
+.B \-h
displays the simple usage.
.SH BUGS