+@verbatim
|
|
+ATM MODE
|
|
+========
|
|
+
|
|
+The atm scli mode is based on the ATM-MIB as published in RFC 2515.
|
|
+This mode is intended to display and configure ATM parameters.
|
|
+
|
|
+ `show atm interface info <regexp>'
|
|
+ `show atm interface details <regexp>'
|
|
+
|
|
+The show atm interface info command displays summary information for
|
|
+all selected ATM interfaces. The optional regular expression <regexp>
|
|
+is matched against the interface descriptions to select the interfaces
|
|
+of interest. The command generates a table with the following columns:
|
|
+
|
|
+
|
|
+INTERFACE network interface number
|
|
+
|
|
+
|
|
+The show atm interface details command describes the selected
|
|
+ATM interfaces in more detail. The optional regular expression
|
|
+<regexp> is matched against the interface descriptions to
|
|
+select the interfaces of interest.
|
|
+
|
|
+BRIDGE MODE
|
|
+===========
|
|
+
|
|
+The scli bridge mode is based on the BRIDGE-MIB as published in RFC
|
|
+1493. It provides commands to browse information specific to LAN
|
|
+bridges (also known as layer two switches).
|
|
+
|
|
+ `show bridge info'
|
|
+ `show bridge ports'
|
|
+ `show bridge stp ports'
|
|
+ `show bridge forwarding'
|
|
+ `show bridge filter'
|
|
+ `show bridge stats'
|
|
+ `monitor bridge stats'
|
|
+
|
|
+The show bridge info command displays summary information about a
|
|
+bridge, such as the number of ports and the supported bridging
|
|
+functions and associated parameters.
|
|
+
|
|
+The show bridge ports command displays information about the bridge
|
|
+ports.
|
|
+
|
|
+The show bridge stp ports command displays information about the bridge
|
|
+ports which participate in the spanning tree protocol. The command
|
|
+generates a table with the following columns:
|
|
+
|
|
+
|
|
+ PORT port number
|
|
+ PRIO spanning tree priority of the port
|
|
+ STATE spanning tree status of the port
|
|
+ P-COST path costs for this port
|
|
+ D-ROOT designated root port
|
|
+ D-COST designated costs
|
|
+ D-BRIDGE designated bridge
|
|
+ D-PORT designated port
|
|
+
|
|
+
|
|
+The status is encoded in two characters. The first character
|
|
+indicates whether STP on the port is enabled (E) or disabled
|
|
+(D). The second character indicates the current status
|
|
+(D=disabled, B=blocking, I=listening, L=learning, F=forwarding,
|
|
+X=broken).
|
|
+
|
|
+The show bridge forwarding command displays the forwarding
|
|
+data base used by transparent bridges. The command generates
|
|
+a table with the following columns:
|
|
+
|
|
+ PORT port number
|
|
+ STATUS status of the forwarding entry
|
|
+ ADDRESS address associated with the port
|
|
+ NAME name of the address (where known)
|
|
+ VENDOR vendor info derived from the address
|
|
+
|
|
+
|
|
+The show bridge filter command shows filtering information.
|
|
+
|
|
+The show bridge stats command displays per port statistics for
|
|
+transparent bridges. The command generates a table with the
|
|
+following columns:
|
|
+
|
|
+ PORT port number
|
|
+ I-FPS input frames per second
|
|
+ O-FPS output frames per second
|
|
+ D-FPS discarded frames per second
|
|
+ DESCRIPTION description of the port
|
|
+
|
|
+
|
|
+The monitor bridge stats command shows the same
|
|
+information as the show bridge stats command. Theinformation is updated periodically.
|
|
+
|
|
+CISCO MODE
|
|
+==========
|
|
+
|
|
+The cisco scli mode is used to display and configure cisco parameters.
|
|
+
|
|
+ `show cisco ip accounting info'
|
|
+ `show cisco ip accounting current'
|
|
+ `show cisco ip accounting snapshot'
|
|
+ `monitor cisco ip accounting current'
|
|
+ `monitor cisco ip accounting snapshot'
|
|
+
|
|
+cisco IP accounting info
|
|
+
|
|
+cisco IP current accounting data
|
|
+
|
|
+cisco IP snapshot accounting data
|
|
+
|
|
+cisco IP current accounting data
|
|
+
|
|
+cisco IP snapshot accounting data
|
|
+
|
|
+DISMAN MODE
|
|
+===========
|
|
+
|
|
+The disman scli mode is based on the DISMAN-SCRIPT-MIB as published in
|
|
+RFC 3165 and the DISMAN-SCHEDULE-MIB as published in RFC 3231. It
|
|
+allows to browse and configure distributed managers.
|
|
+
|
|
+ `create disman script <owner> <name> <description>'
|
|
+ `create disman run <owner> <name> <args>'
|
|
+ `show disman languages'
|
|
+ `show disman script info'
|
|
+ `show disman script details'
|
|
+ `show disman launch info'
|
|
+ `show disman launch details'
|
|
+ `show disman run info'
|
|
+ `show disman run details'
|
|
+ `show disman scheduler info'
|
|
+ `show disman scheduler details'
|
|
+ `monitor disman run'
|
|
+
|
|
+...
|
|
+
|
|
+...
|
|
+
|
|
+languages supported by the distributed manager
|
|
+
|
|
+script summary information
|
|
+
|
|
+scripts installed at the distributed manager
|
|
+
|
|
+launch summary information
|
|
+
|
|
+launch buttons installed on the distributed manager
|
|
+
|
|
+summary information about running scripts
|
|
+
|
|
+running scripts on the distributed manager
|
|
+
|
|
+scheduler information
|
|
+
|
|
+schedules on the distributed manager
|
|
+
|
|
+monitor running scripts
|
|
+
|
|
+ENTITY MODE
|
|
+===========
|
|
+
|
|
+The entity scli mode is based on the ENTITY-MIB as published in RFC
|
|
+2737. It provides commands to browse the physical entities or physical
|
|
+components what make up a managed system.
|
|
+
|
|
+ `show entity info'
|
|
+ `show entity details'
|
|
+ `show entity containment'
|
|
+
|
|
+The show entity info command displays summary information about the
|
|
+physical entities that compose the system. The command generates a
|
|
+table with the following columns:
|
|
+
|
|
+
|
|
+ ENTITY entity number
|
|
+ CLASS class of the entity (see below)
|
|
+ NAME name of the entity
|
|
+ DESCRIPTION description of the entity
|
|
+
|
|
+
|
|
+The show entity details command describes the physical entities
|
|
+in more detail.
|
|
+
|
|
+The show entity containment command displays the physical entity
|
|
+containment hierarchy.
|
|
+
|
|
+ETHERNET MODE
|
|
+=============
|
|
+
|
|
+The ethernet scli mode is based on the EtherLike-MIB as published in
|
|
+RFC 2665 and the MAU-MIB as published in RFC 2668.
|
|
+
|
|
+ `show ethernet mau'
|
|
+ `show ethernet stats'
|
|
+ `monitor ethernet stats'
|
|
+
|
|
+The show ethernet mau command displays information about the medium
|
|
+attachment units (MAUs) for each ethernet port. The command generates a
|
|
+table which has the following columns:
|
|
+
|
|
+
|
|
+ INTERFACE network interface number
|
|
+ MAU medium attachment unit number per interface
|
|
+ STATUS status of the medium attachment unit
|
|
+ MEDIA media availability
|
|
+ JABBER jabber state of the medium attachment unit
|
|
+ AUTONEG autonegation capabilities
|
|
+ TYPE type of the medium attachment unit
|
|
+
|
|
+
|
|
+The show ethernet stats command displays ethernet specific
|
|
+statistics for each ethernet interface. The command outputs
|
|
+a table which has the following columns:
|
|
+
|
|
+ INTERFACE network interface number
|
|
+ ALIGN alignement errors per second
|
|
+ FCS frame check sequence errors per second
|
|
+ RCV MAC receive errors per second
|
|
+ LONG frames exceeding maximum frame size per second
|
|
+ DEFER deferred transmission per second
|
|
+ SCOL single collisions per second
|
|
+ MCOLR multiple collisions per second
|
|
+ XCOL excessive collisions per second
|
|
+ LCOL late collisions per second
|
|
+ XMIT MAC transmit errors per second
|
|
+ CARR carrier sense errors per second
|
|
+
|
|
+
|
|
+The monitor ethernet stats command shows the same information
|
|
+as the show ethernet stats command. The information is updated
|
|
+periodically.
|
|
+
|
|
+INTERFACE MODE
|
|
+==============
|
|
+
|
|
+The scli interface mode is based on the IF-MIB as published in RFC
|
|
+2863. It provides commands to browse, monitor and configure arbitrary
|
|
+network interfaces.
|
|
+
|
|
+ `set interface status <regexp> <status>'
|
|
+ `set interface alias <regexp> <string>'
|
|
+ `set interface notifications <regexp> <value>'
|
|
+ `set interface promiscuous <regexp> <bool>'
|
|
+ `show interface info [<regexp>]'
|
|
+ `show interface details [<regexp>]'
|
|
+ `show interface stack [<regexp>]'
|
|
+ `show interface stats [<regexp>]'
|
|
+ `monitor interface stats [<regexp>]'
|
|
+ `alert interface status <regexp> [<regexp>]'
|
|
+ `dump interface'
|
|
+
|
|
+The set interface status command modifies the administrative status of
|
|
+all selected interfaces. The regular expression <regexp> is matched
|
|
+against the interface descriptions to select the interfaces of
|
|
+interest. The <value> parameter must be one of the strings "up",
|
|
+"down", or "testing".
|
|
+
|
|
+The set interface alias command assigns the alias name <string> to the
|
|
+selected interfaces. The alias name provies a non-volatile 'handle'
|
|
+which can be used by management applications to better identify
|
|
+interfaces. The regular expression <regexp> is matched against the
|
|
+interface descriptions to select the interfaces.
|
|
+
|
|
+The set interface notifications command controls whether the selected
|
|
+interfaces generate linkUp and linkDown notifications. The regular
|
|
+expression <regexp> is matched against the interface descriptions to
|
|
+select the interfaces. The <value> parameter must be one of the strings
|
|
+"enabled" or "disabled".
|
|
+
|
|
+The set interface promiscuous command controls whether the selected
|
|
+interfaces operate in promiscuous mode or not. The regular expression
|
|
+<regexp> is matched against the interface descriptions to select the
|
|
+interfaces. The <bool> parameter must be one of the strings "true" or
|
|
+"false".
|
|
+
|
|
+The show interface info command displays summary information for all
|
|
+selected interfaces. The optional regular expression <regexp> is
|
|
+matched against the interface descriptions to select the interfaces of
|
|
+interest. The command generates a table with the following columns:
|
|
+
|
|
+
|
|
+ INTERFACE network interface number
|
|
+ STATUS interface status (see below)
|
|
+ MTU maximum transfer unit
|
|
+ TYPE type of the network interface
|
|
+ SPEED speed in bits per second
|
|
+ NAME name of the network interface
|
|
+ DESCRIPTION description of the network interface
|
|
+
|
|
+
|
|
+The status is encoded in four characters. The first character
|
|
+indicates the administrative status (U=up, D=down, T=testing).
|
|
+The second character indicates the operational status (U=up,
|
|
+D=down, T=testing, ?=unknown, O=dormant, N=not-present,
|
|
+L=lower-layer-down). The third character indicates whether a
|
|
+connector is present (C=connector, N=none) and the fourth
|
|
+character indicates whether the interface is in promiscuous
|
|
+mode (P=promiscuous, N=normal).
|
|
+
|
|
+The show interface details command describes the selected
|
|
+interfaces in more detail. The optional regular expression
|
|
+<regexp> is matched against the interface descriptions to
|
|
+select the interfaces of interest.
|
|
+
|
|
+The show interface stack command shows the stacking order
|
|
+of the interfaces.
|
|
+
|
|
+The show interface stats command displays network
|
|
+interface statistics for all selected interfaces.
|
|
+The optional regular expression <regexp> is matched
|
|
+against the interface description to select the
|
|
+interfaces. The command outputs a table which has
|
|
+the following columns:
|
|
+
|
|
+ INTERFACE network interface number
|
|
+ STATUS interface status (see above)
|
|
+ I-BPS input bytes per second
|
|
+ O-BPS output bytes per second
|
|
+ I-PPS input packets per second
|
|
+ O-PPS output packets per second
|
|
+ I-ERR input errors per second
|
|
+ O-ERR output errors per second
|
|
+ DESCRIPTION description of the network interface
|
|
+
|
|
+
|
|
+The monitor interface stats command shows the same
|
|
+information as the show interface stats command. The
|
|
+information is updated periodically.
|
|
+
|
|
+The alarm interface status command generates alerts for
|
|
+interfaces that are in given status.
|
|
+
|
|
+The dump interface command generates a sequence of scli commands
|
|
+which can be used to restore the interface configuration.
|
|
+
|
|
+IP MODE
|
|
+=======
|
|
+
|
|
+The ip scli mode is based on the IP-MIB as published in RFC 2011, the
|
|
+IP-FORWARD-MIB as published in RFC 2096, the IP-TUNNEL-MIB as published
|
|
+in RFC 2667 and the RFC1213-MIB as published in RFC 1213. It provides
|
|
+commands to browse, monitor and configure IP protocol engines.
|
|
+
|
|
+ `set ip forwarding <value>'
|
|
+ `set ip ttl <number>'
|
|
+ `show ip info'
|
|
+ `show ip forwarding'
|
|
+ `show ip addresses'
|
|
+ `show ip tunnel'
|
|
+ `show ip mapping'
|
|
+ `dump ip'
|
|
+
|
|
+The set ip forwarding command controls whether the IP protocol engine
|
|
+forwards IP datagrams or not. The <value> parameter must be one of the
|
|
+strings "enabled" or "disabled".
|
|
+
|
|
+The set ip ttl command can be used to change the default time to live
|
|
+(TTL) value used by the IP protocol engine. The <number> parameter must
|
|
+be a number between 1 and 255 inclusive.
|
|
+
|
|
+The show ip info command displays paramters of the IP protocol engine,
|
|
+such as the default TTL or whether the node is forwarding IP packets.
|
|
+
|
|
+The show ip forwarding command displays the IP forwarding data base.
|
|
+The command generates a table with the following columns:
|
|
+
|
|
+
|
|
+ DESTINATION
|
|
+ NEXT HOP
|
|
+ TYPE
|
|
+ PROTO
|
|
+ INTERFACE
|
|
+
|
|
+
|
|
+The show ip addresses command displays the IP addresses assigned
|
|
+to network interfaces. The command generates a table with the
|
|
+following columns:
|
|
+
|
|
+ INTERFACE network interface number
|
|
+ ADDRESS IP address
|
|
+ PREFIX IP address prefix length
|
|
+ NAME name of the IP address
|
|
+
|
|
+
|
|
+The show ip tunnel command displays information about existing
|
|
+IP tunnels.
|
|
+
|
|
+The show ip mapping command displays the mapping of IP address
|
|
+to lower layer address (e.g., IEEE 802 addresses). The command
|
|
+generates a table with the following columns:
|
|
+
|
|
+ INTERFACE network interface number
|
|
+ STATUS status of the mapping entry
|
|
+ ADDRESS IP address
|
|
+ ADDRESS lower layer address
|
|
+
|
|
+
|
|
+The dump ip command generates a sequence of scli commands
|
|
+which can be used to restore the IP configuration.
|
|
+
|
|
+NETSNMP MODE
|
|
+============
|
|
+
|
|
+The netsnmp scli mode is used to display and configure netsnmp specific
|
|
+parameters. It is based on the UCD-SNMP-MIB.
|
|
+
|
|
+ `set netsnmp debugging <value>'
|
|
+ `set netsnmp restart'
|
|
+ `show netsnmp info'
|
|
+ `show netsnmp load'
|
|
+ `show netsnmp exec'
|
|
+ `show netsnmp proc'
|
|
+ `dump netsnmp'
|
|
+
|
|
+The set netsnmp debugging command controls whether the agent generates
|
|
+debug messages or not. The <value> parameter must be one of the strings
|
|
+"enabled" or "disabled".
|
|
+
|
|
+The set netsnmp restart command restarts the agent.
|
|
+
|
|
+The show netsnmp info command shows general information about the
|
|
+netsnmp/ucdsnmp agent such as the version number and the software
|
|
+configuration.
|
|
+
|
|
+The show netsnmp load command shows the system's load.
|
|
+
|
|
+The show netsnmp exec command shows information about pre-configured
|
|
+commands that can be invoked.
|
|
+
|
|
+The show netsnmp proc command shows information about which processes
|
|
+netsnmp watches.
|
|
+
|
|
+The dump netsnmp command generates a sequence of scli commands which
|
|
+can be used to restore the netsnmp specific configuration.
|
|
+
|
|
+NORTEL MODE
|
|
+===========
|
|
+
|
|
+The nortel scli mode allows to manipulate virtual lans (vlans) on
|
|
+nortel bridges. It is based on the RAPID-CITY MIB which is implemented
|
|
+at least on the baystack bridges.
|
|
+
|
|
+ `create nortel bridge vlan <vlanid> <name>'
|
|
+ `delete nortel bridge vlan <regexp>'
|
|
+ `set nortel bridge vlan ports <regexp> <ports>'
|
|
+ `set nortel bridge vlan default <string> <ports>'
|
|
+ `show nortel bridge vlan info [<regexp>]'
|
|
+ `show nortel bridge vlan details [<regexp>]'
|
|
+ `show nortel bridge vlan ports'
|
|
+ `dump nortel bridge vlan'
|
|
+
|
|
+The create nortel bridge vlan command is used to create a new vlan with
|
|
+the given <vlanid> and <name>.
|
|
+
|
|
+The delete nortel bridge vlan command deletes all selected vlans. The
|
|
+regular expression <regexp> is matched against the vlan names to select
|
|
+the vlans that should be deleted.
|
|
+
|
|
+The set nortel bridge vlan ports command allows to assign ports to
|
|
+port-based vlans. The regular expression <regexp> is matched against
|
|
+the vlan names to select the vlans that should be modified. The <ports>
|
|
+argument contains a comma separated list of port numbers or port number
|
|
+ranges, e.g. 1,5,7-8.
|
|
+
|
|
+The set nortel bridge vlan default command allows to assign ports to a
|
|
+default vlan. The <string> argument is matched against the vlan names
|
|
+to select the vlan. The <ports> argument contains a comma separated
|
|
+list of port numbers or port number ranges, e.g. 1,5,7-8.
|
|
+
|
|
+The show nortel bridge vlan info command shows summary information
|
|
+about all selected vlans. The optional regular expression <regexp> is
|
|
+matched against the vlan names to select the vlans of interest. The
|
|
+command generates a table with the following columns:
|
|
+
|
|
+
|
|
+ VLAN vlan number
|
|
+ STATUS status of the vlan (see below)
|
|
+ NAME vlan name
|
|
+ PORTS ports assigned to the vlan
|
|
+
|
|
+
|
|
+The status is encoded in four characters. The first character
|
|
+indicates the status of the row (A=active, S=not in service,
|
|
+R=not ready). The second character indicates vlan type (P=B
|
|
+port, I=IP-subnet, O=protocol, S=src address, D=dst address).
|
|
+The third character indicates the priority of the vlan (H=high,
|
|
+N=normal) and the fourth character indicates whether routing
|
|
+is enabled (R=routing, N=no routing).
|
|
+
|
|
+The show nortel bridge vlan details command describes the
|
|
+selected vlans in more detail. The optional regular expression
|
|
+<regexp> is matched against the vlan names to select the vlans
|
|
+of interest.
|
|
+
|
|
+The show nortel bridge vlan ports command shows information
|
|
+for each vlan port. The command generates a table with the
|
|
+following columns:
|
|
+
|
|
+ PORT port number
|
|
+ FLAGS port vlan flags (see below)
|
|
+ DEFAULT default vlan number
|
|
+ VLANS vlan numbers the port is member of
|
|
+
|
|
+
|
|
+The flags are encoded in four characters. The first character
|
|
+indicates the port type (A=access, T=trunk). The second character
|
|
+indicates whether the port tags frames (T=tagging, N=none). The
|
|
+third character indicates whether the port discards tagged frames
|
|
+(D=discard, N=none) and the fourth character indicates whether
|
|
+the port discards untagged frames (D=discard, N=none).
|
|
+
|
|
+The dump nortel bridge vlan command generates a sequence of scli
|
|
+commands which can be used to restore the vlan configuration.
|
|
+
|
|
+OSPF MODE
|
|
+=========
|
|
+
|
|
+The scli ospf mode is used to display and configure OSPF parameters.
|
|
+
|
|
+ `show ospf area'
|
|
+ `show ospf info'
|
|
+ `show ospf interface'
|
|
+
|
|
+show OSPF areas
|
|
+
|
|
+general OSPF information
|
|
+
|
|
+show OSPF interfaces
|
|
+
|
|
+PRINTER MODE
|
|
+============
|
|
+
|
|
+The scli printer mode is based on the Printer-MIB as published in RFC
|
|
+1759 and some updates currently being worked on in the IETF Printer MIB
|
|
+working group.
|
|
+
|
|
+ `show printer info'
|
|
+ `show printer covers'
|
|
+ `show printer inputs'
|
|
+ `show printer outputs'
|
|
+ `show printer markers'
|
|
+ `show printer supplies'
|
|
+ `show printer interpreter'
|
|
+ `show printer console display'
|
|
+ `show printer console lights'
|
|
+ `show printer alerts'
|
|
+ `monitor printer console display'
|
|
+ `monitor printer console lights'
|
|
+ `monitor printer alerts'
|
|
+
|
|
+The show printer info command shows general information about the
|
|
+printer including global status information.
|
|
+
|
|
+The show printer covers command shows information about the covers of a
|
|
+printer.
|
|
+
|
|
+The show printer inputs command shows information about the input
|
|
+sub-units of a printer which provide media for input to the printing
|
|
+process.
|
|
+
|
|
+The show printer output command shows information about the output
|
|
+sub-units of a printer capable of receiving media delivered from the
|
|
+printing process.
|
|
+
|
|
+The show printer markers command shows information about the marker
|
|
+sub-units of a printer which produce marks on the print media.
|
|
+
|
|
+The show printer supplies command shows information about the supplies
|
|
+which are consumed and the waste produced by the markers of a printer.
|
|
+
|
|
+The show printer interpreter command shows information about the page
|
|
+description language and control language interpreters supported by the
|
|
+printer.
|
|
+
|
|
+The show printer console display command shows the current contents of
|
|
+the printer's display. The command generates a table with the following
|
|
+columns:
|
|
+
|
|
+
|
|
+ PRINTER logical printer number
|
|
+ LINE display line number
|
|
+ TEXT contents of the display line
|
|
+
|
|
+
|
|
+The show printer console lights command shows the current
|
|
+status of the printer's lights. The command generates a table
|
|
+with the following columns:
|
|
+
|
|
+ PRINTER logical printer number
|
|
+ LIGHT number identifying the light/led
|
|
+ DESCRIPTION description of the light/led
|
|
+ STATUS current status (on, off, blink)
|
|
+ COLOR current color of the light
|
|
+
|
|
+
|
|
+The show printer alerts command displays the list of active
|
|
+printer alerts including the alert code, the alert severity,
|
|
+the alert description, the alert time, the alert location and
|
|
+the personel required to handle the alert.
|
|
+
|
|
+The monitor printer console display command shows the same
|
|
+information as the show printer console display command. The
|
|
+information is updated periodically.
|
|
+
|
|
+The monitor printer console lights command shows the same
|
|
+information as the show printer console lights command. The
|
|
+information is updated periodically.
|
|
+
|
|
+The monitor printer alerts command shows the same information
|
|
+as the show printer alerts command. The information is updated
|
|
+periodically.
|
|
+
|
|
+SCLI MODE
|
|
+=========
|
|
+
|
|
+The scli mode provides commands that can be used to display and
|
|
+manipulate the internal state of the scli interpreter.
|
|
+
|
|
+ `open <nodename> [<community>]'
|
|
+ `close'
|
|
+ `create scli plugin <module>'
|
|
+ `delete scli plugin <module>'
|
|
+ `exit'
|
|
+ `help'
|
|
+ `history'
|
|
+ `create scli alias <name> <value>'
|
|
+ `delete scli alias <regexp>'
|
|
+ `set scli regex [<regexp>]'
|
|
+ `set scli debugging [<regexp>]'
|
|
+ `set scli pager <pager>'
|
|
+ `set scli format <fmt>'
|
|
+ `show scli info'
|
|
+ `show scli commands'
|
|
+ `show scli aliases'
|
|
+ `show scli modes [<regex>]'
|
|
+ `show scli schema [<regex>]'
|
|
+ `show scli alarm info'
|
|
+
|
|
+The open command establishes an association to a remote SNMP agent. The
|
|
+<nodename> argument is the DNS name or the IP address of the remote
|
|
+node. Scli will try to talks to this node's SNMP agent on the default
|
|
+port number (usually 161) using the default transport mapping (usually
|
|
+SNMP over UDP). The optional <community> argument is the community
|
|
+string needed to communicate with the remote SNMP agent. The default
|
|
+community string is "public". Opening an association while an
|
|
+association is already established is not considered an error. The
|
|
+existing established association will be closed automatically before an
|
|
+attempt to create a new association is started.
|
|
+
|
|
+The close command closes an established association to a remote SNMP
|
|
+agent. Invoking the close command when no association is established is
|
|
+not considered an error and will do just nothing.
|
|
+
|
|
+The create scli plugin command dynamically loads an scli mode into a
|
|
+running scli process. This can be used to dynamically extend scli with
|
|
+modules coming from other sources. Dynamic loadable modules also
|
|
+simplify the development and management of site-specific modules.
|
|
+
|
|
+The delete scli plugin command removes a previously loaded modules from
|
|
+a running scli process.
|
|
+
|
|
+The exit command terminates the scli interpreter. An end of file in the
|
|
+standard input stream will also terminate the the scli interpreter.
|
|
+
|
|
+The help command displays some help information including a list of all
|
|
+top-level scli commands.
|
|
+
|
|
+The history command displays the scli command history list with line
|
|
+numbers.
|
|
+
|
|
+The create scli alias command creates the alias <name> for the scli
|
|
+command (fragment) <value>. If the alias <name> already exists, then
|
|
+the new <value> will be assigned to the existing alias.
|
|
+
|
|
+The delete scli alias command removes previously defined aliases from
|
|
+the scli interpreter. The regular expression <regexp> is matched
|
|
+against all alias names in order to select the aliases that are deleted.
|
|
+
|
|
+The set scli regex command controls how scli matches regular
|
|
+expressions. The optional regular expression <regexp> is matched
|
|
+against the regular expression options. A successful match turns a
|
|
+regular expression option on while an unsuccessful match turns a
|
|
+regular expression option off. Invoking the command without the
|
|
+<regexp> argument will turn all regular expression options off. The
|
|
+currently defined regular expression options are "extended" for POSIX
|
|
+extended regular expressions and "case-insensitive" for case
|
|
+insensitive matches.
|
|
+
|
|
+The set scli debugging command sets the debugging level of the SNMP
|
|
+engine. The optional regular expression <regexp> is matched against the
|
|
+debugging levels. A successful match turns a debugging level on while
|
|
+an unsuccessful match turns a debugging level off. Invoking the command
|
|
+without the <regexp> argument will turn all debugging levels off. The
|
|
+currently defined debugging levels are "session" for the SNMP session
|
|
+layer, "request" for the SNMP request handling layer, "transport" for
|
|
+the SNMP transport layer, "packet" for the SNMP packet layer, and
|
|
+"asn1" for the ASN.1 coding layer.
|
|
+
|
|
+The set scli pager command defines the shell command which is used as a
|
|
+pager if the output produced by an scli command does not fit on a
|
|
+single screen. The output is passed to the <pager> shell command via
|
|
+its standard input stream.
|
|
+
|
|
+The set scli format command defines the output format used by
|
|
+subsequent scli commands. The currently supported formats are "scli"
|
|
+and "xml". The "scli" format is the default output format and described
|
|
+in this documentation. The "xml" output format is experimental and
|
|
+therefore not described here.
|
|
+
|
|
+The show scli info command displays the current status of the scli
|
|
+interpreter.
|
|
+
|
|
+The show scli commands command displays the scli command tree. The
|
|
+full command syntax is displayed for each leaf node.
|
|
+
|
|
+The show scli aliases command lists all scli command aliases. The
|
|
+first column in the generated table lists the aliase names while the
|
|
+second column shows the alias values.
|
|
+
|
|
+The show scli modes command shows information about the scli modes. An
|
|
+scli mode is a logical grouping of related commands (e.g., all commands
|
|
+that deal with printers). The optional regular expression <regex> can
|
|
+be use to select a subset of the available scli modes.
|
|
+
|
|
+The show scli schema command produces xml schema definitions for the
|
|
+selected scli modes. An scli mode is a logical grouping of related
|
|
+commands (e.g., all commands that deal with printers). The optional
|
|
+regular expression <regex> can be use to select a subset of the
|
|
+available scli modes.
|
|
+
|
|
+The show scli alarm info command displays summary information about all
|
|
+known alarms.
|
|
+
|
|
+SNMP MODE
|
|
+=========
|
|
+
|
|
+The snmp scli mode is based on the SNMPv2-MIB as published in RFC 1907,
|
|
+the SNMP-FRAMEWORK-MIB as published in RFC 2571, the
|
|
+SNMP-USER-BASED-SM-MIB as published in RFC 2574, the
|
|
+SNMP-VIEW-BASED-ACM-MIB as published in RFC 2575, the SNMP-TARGET-MIB
|
|
+as published in RFC 2573, and the SNMP-NOTIFICATION-MIB as published in
|
|
+RFC 2573.
|
|
+
|
|
+ `create snmp vacm member <name> <group> [<model>]'
|
|
+ `delete snmp vacm member <regex-name> <regex-group> [<model>]'
|
|
+ `set snmp authentication traps <status>'
|
|
+ `show snmp engine'
|
|
+ `show snmp resources'
|
|
+ `show snmp vacm member'
|
|
+ `show snmp vacm access'
|
|
+ `show snmp vacm views'
|
|
+ `show snmp usm users'
|
|
+ `show snmp target addresses'
|
|
+ `show snmp target parameters'
|
|
+ `show snmp notification targets'
|
|
+ `dump snmp'
|
|
+
|
|
+The create snmp vacm member commands can be used to assign new members
|
|
+(security names) to vacm groups. New groups are created if they do not
|
|
+exist.
|
|
+
|
|
+The delete snmp vacm member commands can be used to delete members
|
|
+(security names) from vacm groups. Groups are deleted if the last
|
|
+member is deleted.
|
|
+
|
|
+The set snmp authentication traps command controls whether the SNMP
|
|
+engine generates authentication failure notifications. The <value>
|
|
+parameter must be one of the strings "enabled" or "disabled".
|
|
+
|
|
+The show snmp engine command displays information about the SNMP
|
|
+protocol engine such as the number of boots, the current time relative
|
|
+to the last boot and the maximum message size.
|
|
+
|
|
+The show snmp resources command displays information about the MIB
|
|
+resources supported by the SNMP agent.
|
|
+
|
|
+The show snmp vacm member command displays the mapping of security
|
|
+names to group names. The command generates a table with the following
|
|
+columns:
|
|
+
|
|
+
|
|
+ ROW row storage type and status
|
|
+ MOD security model
|
|
+ NAME member name (security name)
|
|
+ GROUP name of the vacm group
|
|
+
|
|
+
|
|
+The show snmp vacm access command display the access control
|
|
+rules for the security groups. The command generates a table
|
|
+with the following columns:
|
|
+
|
|
+ ROW row storage type and status
|
|
+ GROUP security group name
|
|
+ MOD security model
|
|
+ LVL security level (--, a-, ap)
|
|
+ CTX context name
|
|
+ MATCH match (exact or prefix)
|
|
+ READ view name for read access
|
|
+ WRITE view name for write access
|
|
+ NOTIFY view name for notification
|
|
+
|
|
+
|
|
+The show snmp vacm views command displays MIB view definitions.
|
|
+The command generates a table with the following columns:
|
|
+
|
|
+ ROW row storage type and status
|
|
+ VIEW view name
|
|
+ TYPE access to the view subtree (incl/excl)
|
|
+ PREFIX object identifier wildcard prefix
|
|
+
|
|
+
|
|
+The show snmp usm users command displays the configured users.
|
|
+The command generates a table with the following columns:
|
|
+
|
|
+ ROW row storage type and status
|
|
+ USER USM user name
|
|
+ NAME security name of the USM user
|
|
+ AUTH authentication protocol
|
|
+ PRIV privacy protocol
|
|
+
|
|
+
|
|
+The show snmp target addresses command displays information
|
|
+about the configured SNMP target addresses. The command
|
|
+generates a table with the following columns:
|
|
+
|
|
+ ROW row storage type and status
|
|
+ TARGET target name
|
|
+ DOMAIN transport domain
|
|
+ ADDRESS transport address
|
|
+ TMOUT timeout value in ms
|
|
+ RETRY number of retries
|
|
+ PARAMS associated parameters
|
|
+ TAGS tag list
|
|
+
|
|
+
|
|
+The show snmp target parameters command displays information
|
|
+about the configured SNMP target parameters. The command
|
|
+generates a table with the following columns:
|
|
+
|
|
+ ROW row storage type and status
|
|
+ PARAMS parameter name
|
|
+ NAME security name
|
|
+
|
|
+
|
|
+The show snmp notification targets command displays information
|
|
+about the configured SNMP notification targets. The command
|
|
+generates a table with the following columns:
|
|
+
|
|
+ ROW row storage type and status
|
|
+ NAME notification target name
|
|
+ TYPE notification type
|
|
+ TAG tag reference to targets
|
|
+
|
|
+
|
|
+The dump snmp command generates a sequence of scli commands
|
|
+which can be used to restore the engine configuration.
|
|
+
|
|
+SYSTEM MODE
|
|
+===========
|
|
+
|
|
+The system scli mode is primarily based on the SNMPv2-MIB as published
|
|
+in RFC 1907 and the HOST-RESOURCES-MIB as publisched in RFC 2790. It
|
|
+can be used to browse and configure system parameters and
|
|
+characteristics.
|
|
+
|
|
+ `set system contact <string>'
|
|
+ `set system name <string>'
|
|
+ `set system location <string>'
|
|
+ `show system info'
|
|
+ `show system devices'
|
|
+ `show system storage'
|
|
+ `show system mounts'
|
|
+ `show system processes [<regexp>]'
|
|
+ `monitor system storage'
|
|
+ `monitor system processes [<regexp>]'
|
|
+ `dump system'
|
|
+
|
|
+The set system contact command configures the system's contact
|
|
+information. The <string> argument should include information on how to
|
|
+contact a person who is responsible for this system.
|
|
+
|
|
+The set system name command configures the systems's name. By
|
|
+convention, this is the system's fully-qualified domain name.
|
|
+
|
|
+The set system location command configures the system's physical
|
|
+location.
|
|
+
|
|
+The show system info command shows general information about the system.
|
|
+
|
|
+The show system devices command shows a list of system devices. The
|
|
+command generates a table with the following columns:
|
|
+
|
|
+
|
|
+ INDEX device number
|
|
+ STATUS current status of the device
|
|
+ DESCRIPTION description of the device
|
|
+
|
|
+
|
|
+The show system storage command displays information about the
|
|
+logical areas attached in the system. The command generates a
|
|
+table with the following columns:
|
|
+
|
|
+ INDEX logical storage area number
|
|
+ DESCRIPTION description of the storage area
|
|
+ TYPE logical storage area type
|
|
+ SIZE total size of the storage area
|
|
+ USED amount of storage in use
|
|
+ FREE amount of storage available
|
|
+ USE% used storage in percent
|
|
+
|
|
+
|
|
+The show system mounts command shows the list of filesystems
|
|
+mounted on the system. The command generates a table with the
|
|
+following columns:
|
|
+
|
|
+ INDEX filesystem identification number
|
|
+ LOCAL local root path name of the filesystem
|
|
+ REMOTE remote server and root path name (if any)
|
|
+ TYPE filesytem type (if known)
|
|
+ OPTIONS access mode (ro/rw) and boot flag
|
|
+
|
|
+
|
|
+The show system processes command display information about the
|
|
+processes currently running on the system. The regular expression
|
|
+<regexp> is matched against the command executed by the process
|
|
+to select the processes of interest.The command generates a table
|
|
+with the following columns:
|
|
+
|
|
+ PID process identification number
|
|
+ S status of the process (see below)
|
|
+ T type of the process (see below)
|
|
+ MEMORY memory used by the process
|
|
+ TIME CPU time used by the process
|
|
+ COMMAND command executed by the process
|
|
+
|
|
+
|
|
+The process status values are C=running, R=runnable,
|
|
+S=not runnable, and Z=invalid. The process types values are
|
|
+?=unknown, O=operating system, D=device driver, and A=application.
|
|
+
|
|
+The monitor system storage command shows the same
|
|
+information as the show system storage command. The
|
|
+information is updated periodically.
|
|
+
|
|
+The monitor system processes command show the same
|
|
+information as the show system processes command. The
|
|
+information is updated periodically.
|
|
+
|
|
+The dump system command generates a sequence of scli commands
|
|
+which can be used to restore the system configuration.
|
|
+
|
|
+TCP MODE
|
|
+========
|
|
+
|
|
+The scli tcp mode is based on the TCP-MIB as published in RFC 2012. It
|
|
+provides commands to browse information specific to the TCP transport
|
|
+protocol.
|
|
+
|
|
+ `show tcp listener'
|
|
+ `show tcp connections'
|
|
+ `monitor tcp connections'
|
|
+
|
|
+The show tcp listener command displays the listening TCP endpoints.
|
|
+
|
|
+The show tcp connections command displays the connected TCP endpoints
|
|
+including the current state of the connection as seen by the remote
|
|
+SNMP agent.
|
|
+
|
|
+The monitor tcp connections command displays the connected TCP
|
|
+endpoints including the current state of the connection as seen by the
|
|
+remote SNMP agent. The information is updated periodically.
|
|
+
|
|
+UDP MODE
|
|
+========
|
|
+
|
|
+The scli udp mode is based on the UDP-MIB as published in RFC 2013. It
|
|
+provides commands to browse information specific to the UDP transport
|
|
+protocol.
|
|
+
|
|
+ `show udp listener'
|
|
+ `show udp stats'
|
|
+
|
|
+The show udp listener command displays the listening UDP endpoints.
|
|
+
|
|
+The show udp statistics about datagrams received or sent.
|
|
+
|
|
+@end verbatim
|