GCC forwards the -N flag directly to ld. This flag is not documented and
not supported by (for example) Clang. Just use -Wl,-N.
Submitted by: Pawel Worach
- use correct size (512) while reading a gang block
- skip holes while reading child blocks
- advance buffer pointer while reading child blocks
PR: 144214
MFC after: 10 days
o DB-88F5182
o DB-88F5281
o DB-88F6281
o DB-78100
o SheevaPlug
This also includes device tree bindings definitions for some newly introduced
nodes (mpp, gpio).
Reviewed by: imp
Sponsored by: The FreeBSD Foundation
o This is disabled by default for now, and can be enabled using WITH_FDT at
build time.
o Tested with ARM and PowerPC.
Reviewed by: imp
Sponsored by: The FreeBSD Foundation
locate a high memory area for the heap using the SMAP.
- Read the number of hard drive devices from the BIOS instead of hardcoding
a limit of 128. Some BIOSes duplicate disk devices once you get beyond
the maximum drive number.
MFC after: 1 month
bottom of the manpages and order them consistently.
GNU groff doesn't care about the ordering, and doesn't even mention
CAVEATS and SECURITY CONSIDERATIONS as common sections and where to put
them.
Found by: mdocml lint run
Reviewed by: ru
HAL/Fujitsu) CPUs. For the most part this consists of fleshing out the
MMU and cache handling, it doesn't add pmap optimizations possible with
these CPU, yet, though.
With these changes FreeBSD runs stable on Fujitsu Siemens PRIMEPOWER 250
and likely also other models based on SPARC64 V like 450, 650 and 850.
Thanks go to Michael Moll for providing access to a PRIMEPOWER 250.
This driver was written by Alexander Pohoyda and greatly enhanced
by Nikolay Denev. I don't have these hardwares but this driver was
tested by Nikolay Denev and xclin.
Because SiS didn't release data sheet for this controller, programming
information came from Linux driver and OpenSolaris. Unlike other open
source driver for SiS190/191, sge(4) takes full advantage of TX/RX
checksum offloading and does not require additional copy operation in
RX handler.
The controller seems to have advanced offloading features like VLAN
hardware tag insertion/stripping, TCP segmentation offload(TSO) as
well as jumbo frame support but these features are not available
yet. Special thanks to xclin <xclin<> cs dot nctu dot edu dot tw>
who sent fix for receiving VLAN oversized frames.
but also of different types, f.e. Sun Fire V890 can be equipped with a
mix of UltraSPARC IV and IV+ CPUs, requiring different MMU initialization
and different workarounds for model specific errata. Therefore move the
CPU implementation number from a global variable to the per-CPU data.
Functions which are called before the latter is available are passed the
implementation number as a parameter now.
OpenBSD and OpenSolaris do instead of fiddling with the MMUs ourselves.
Unlike direct access the firmware methods don't automatically use the
next free (?) TLB slot, instead the slot to be used has to be specified.
We allocate the TLB slots for the kernel top-down as OpenSolaris suggests
that the firmware will always allocate the ones for its own use bottom-up.
Besides being simpler, according to OpenBSD using the firmware methods is
required to allow booting on Sun Fire E10K with multi-systemboard domains.
of Sun Fire V1280 doesn't round up the size itself but instead lets
claiming of non page-sized amounts of memory fail.
- Change parameters and variables related to the TLB slots to unsigned
which is more appropriate.
- Search the whole OFW device tree instead of only the children of the
root nexus device for the BSP as starting with UltraSPARC IV the 'cpu'
nodes hang off of from 'cmp' (chip multi-threading processor) or 'core'
or combinations thereof. Also in large UltraSPARC III based machines
the 'cpu' nodes hang off of 'ssm' (scalable shared memory) nodes which
group snooping-coherency domains together instead of directly from the
nexus.
- Add support for UltraSPARC IV and IV+ BSPs. Due to the fact that these
are multi-core each CPU has two Fireplane config registers and thus the
module/target ID has to be determined differently so the one specific
to a certain core is used. Similarly, starting with UltraSPARC IV the
individual cores use a different property in the OFW device tree to
indicate the CPU/core ID as it no longer is in coincidence with the
shared slot/socket ID.
While at it additionally distinguish between CPUs with Fireplane and
JBus interconnects as these also use slightly different sizes for the
JBus/agent/module/target IDs.
- Check the return value of init_heap(). This requires moving it after
cons_probe() so we can panic when appropriate. This should be fine as
the PowerPC OFW loader uses that order for quite some time now.
Note that due to e.g. write throttling ('wdrain'), it can stall all the disk
I/O instead of just the device it's configured for. Using it for removable
media is therefore not a good idea.
Reviewed by: pjd (earlier version)
kern.ngroups+1. kern.ngroups can range from NGROUPS_MAX=1023 to
INT_MAX-1. Given that the Windows group limit is 1024, this range
should be sufficient for most applications.
MFC after: 1 month
as this only allows us to access file systems that EFI knows about.
With a loader that can only use EFI-supported file systems, we're
forced to put /boot on the EFI system partition. This is suboptimal
in the following ways:
1. With /boot a symlink to /efi/boot, mergemaster complains about
the mismatch and there's no quick solution.
2. The EFI loader can only boot a single version of FreeBSD. There's
no way to install multiple versions of FreeBSD and select one
at the loader prompt.
3. ZFS maintains /boot/zfs/zpool.cache and with /boot a symlink we
end up with the file on a MSDOS file system. ZFS does not have
proper handling of file systems that are under Giant.
Implement a disk device based on the block I/O protocol instead and
pull in file system code from libstand. The disk devices are really
the partitions that EFI knows about.
This change is backward compatible.
MFC after: 1 week
by keeping it opened after the first open and closing it via the
cleanup handler when NETIF_OPEN_CLOSE_ONCE is defined in order to
avoid the open-close-dance on every file access which with firmware
that for example performs an auto-negotiation on every open causes
netbooting to take horribly long. Basically the behavior with this
knob enabled resembles the one employed between r60506 and r177108
(and for sparc64 also again since r182919) with the addition that
the network device now is closed eventually before entering the
kernel and before rebooting. Actually I think this should be the
desired MI behavior, however the U-Boot loader actually requires
net_close() to be called after every transaction in order for some
local shutdown operations to be performed (and which I think thus
will break on concurrent opens, i.e. when netdev_opens is > 1, like
the loader does at least for disks when LOADER_GZIP_SUPPORT is
enabled).
- Use NETIF_OPEN_CLOSE_ONCE to replace the hack, which artificially
increased netdev_opens for sparc64 in order to keep the network
device opened forever, as at least some firmware versions require
the network device to be closed eventually before entering the
kernel or otherwise will DMA received packets to stale memory.
The powerpc OFW loader probably wants NETIF_OPEN_CLOSE_ONCE to be
set as well for the same reasons.
for each vdev's status. Booting from a degraded vdev should now be
more robust.
Submitted by: Matt Reimer <mattjreimer at gmail.com>
Sponsored by: VPOP Technologies, Inc.
MFC after: 2 weeks
It's based on the newest i386's one and has the advantage of:
- ELF binary support.
- UFS2 filesystem support.
- Many FreeBSD slices support on a disk.
Tested by: SATOU Tomokazu ( tomo1770 _ maple _ ocn _ ne _ jp ),
WATANABE Kazuhiro ( CQG00620 _ nifty _ ne _ jp ) and
nyan
MFC after: 2 week
Happy New Year in Japan!!