if_xname, if_dname, and if_dunit. if_xname is the name of the interface
and if_dname/unit are the driver name and instance.
This change paves the way for interface renaming and enhanced pseudo
device creation and configuration symantics.
Approved By: re (in principle)
Reviewed By: njl, imp
Tested On: i386, amd64, sparc64
Obtained From: NetBSD (if_xname)
dcons(4): very simple console and gdb port driver
dcons_crom(4): FireWire attachment
dconschat(8): User interface to dcons
Tested with: i386, i386-PAE, and sparc64.
* Uppercase the .Dt command contents.
* Remove incorrect usage of .Fa.
* Use .Va for struct members, and .Vt for structs
(correct replacement for .Fa)
* Markup VM_* and MAP_* macros with .Dv command.
* Replace 'man' with 'manual' for consistency.
* Uppercase .Dt command contents.
* Make use of .Fo and .Fc for marking up functions with
a lot of arguments.
NOTE: Please do not use the `\' line seperator for mdoc(7)
manual pages, as it has problems of its own on some displays;
instead, consult the mdoc(7) manual on using .Fo and .Fc.
* Change 'man' to 'manual' for consistency.
* Add .Vt in the right places, transform some .Fa to .Vt, depending
on discussion context.
* When refering to the function malloc(), use .Fn, and not .Xr.
* Add `The' to prefix a sentence when describing a function, so
it results in ``The xxx() function..."
* Use `system call' instead of `syscall'.
* Improve the sentence which discusses accept_filt_generic_mod_event();
Talk about moduledata_t, and refer to the DECLARE_MODULE(9) manual
page.
* Properly markup .An (Author Name) throughout the AUTHORS section.
* Remove first person sentence start.
* Make use of .Dv for LEASE_READ and LEASE_WRITE.
* Move the LOCKS section below the standard mdoc(7) RETURN VALUES
section.
* Cleanup grammar for RETURN VALUES and AUTHORS section.
* Remove redundant sentence on return values.
rate is how fast modems exchange symbols. Bit rate is how many bits
per second the serial port nominally communicates at. Try to use bit
rate consistently where that's what is ment. The default data rate is
now 9600 baud. 300 baud being default pre-dates 4.4-LITE1. Document
that tip doesn't respect the system default rate for a given channel.
Sorry guys, but no ucbvax, kremvax or kgbvax added to the example.
Noted by: bde
what the entry does for people that are not used to reading
/etc/remote files every day. Keep arpavax, because it is a cool name,
but remove the phone number listed. arpavax hasn't been answering
that number for a while :-)
FreeBSD supports. None of them support an alternate formats, except
the alpha (which prints extra register information).
# if we get a mips port, we can put the mips case back to document the
# actual behavior.