seem to be necessary anymore, and it prevents tasting a valid drive
when booting with geom_vinum already loaded, since SCSI disks set their
sectorsize not until first opening them.
shared-last-sector problem.
After this change, even if there is more than one provider with the same
last sector, the proper one will be chosen based on its size.
It still doesn't fix the 'c' partition problem (when da0s1 can be confused
with da0s1c) and situation when 'a' partition starts at offset 0
(then da0s1a can be confused with da0s1 and da0s1c). One can use '-h'
option there, when creating device or avoid sharing last sector.
Actually, when providers share the same last sector and their size is equal,
they provide exactly the same data, so the name (da0s1, da0s1a, da0s1c)
isn't important at all.
- Provide backward compatibility.
- Update copyright's year.
MFC after: 1 week
the previous one failed and there are more than one plex in the volume.
This could have led to a flood of error messages on the console and
probably a deadlock in certain situations.
patch from kan@).
Pull bufobj_invalbuf() out of vinvalbuf() and make g_vfs call it on
close. This is not yet a generally safe function, but for this very
specific use it is safe. This solves the problem with buffers not
being flushed by unmount or after failed mount attempts.
This flag means "wait for all pending requests before returning to userland".
There are pending events for sure, because we just created new provider and
other classes want to taste it, but we cannot answer on I/O requests until
we're here.
4 mutex operations per I/O requests.
- Use only one mutex to protect both (incoming and outgoing) queue.
As MUTEX_PROFILING(9) shows, there is no big contention for this lock.
- Protect sc_queue_count with queue mutex, instead of doing atomic
operations on it.
- Remove DROP_GIANT()/PICKUP_GIANT() - ggate is marked as MPSAFE and no
Giant there.
in BSD class, ie. if provider below us uses the same metadata, don't
create slices based on the metadata.
This allows to create slices on geoms with rank != 1 without hacks.
Discussed with: phk
Approved by: phk
MFC after: 2 weeks
the given providers. Without even one of the configured components there
should be no way to get the secret.
Supported by: WHEEL Sp. z o.o.
http://www.wheel.pl
(we ignore it).
- Remove code used for handling spoil events, as spoiling is not possible
anymore, because we keep consumers open for writing all the time.
MFC after: 4 days
After this change, when component is disconnected because of an I/O error,
it will not be connected and synchronized automatically, it will be logged
as broken and skipped. Autosynchronization can occur, when component is
disconnected (on orphan event) and connected again - there were no I/O
error, so there is no need to not connected the component, but when there were
writes while it wasn't connected, it will be synchronized.
This fix cases, when component is disconnected because of I/O error and can be
connected again and again.
- Bump version number.
- Implement backward compatibility mechanism. After this change when metadata in
old version is detected, it is automatically upgraded to the new (current)
version.
After this change, when component is disconnected because of an I/O error,
it will not be connected and synchronized automatically, it will be logged
as broken and skipped. Autosynchronization can occur, when component is
disconnected (on orphan event) and connected again - there were no I/O
error, so there is no need to not connected the component, but when there were
writes while it wasn't connected, it will be synchronized.
This fix cases, when component is disconnected because of I/O error and can be
connected again and again.
- Bump version number.
- Add version change history.
- Implement backward compatibility mechanism. After this change when metadata in
old version is detected, it is automatically upgraded to the new (current)
version.