crusty, and this still isn't perfect, but its at least a bit more recent. Secondly, a few improvements to the driver from Andrew Boyer, support hint to allow devices to not attach, add VLAN_HWTSO capability so vlans can use TSO, fix in the interrupt handler to make sure the stack TX queue is processed. Oh, and also make sure IPv6 does not cause a re-init in the ioctl routine. Thanks for your efforts Andrew! Thanks to Claudio Jeker for noticing the ixgbe_xmit() routine was not correctly swapping the dma map from the first to the last descriptor in a multi-descriptor transmission, corrected this.
324 lines
12 KiB
Plaintext
324 lines
12 KiB
Plaintext
FreeBSD Driver for Intel(R) Ethernet 10 Gigabit PCI Express Server Adapters
|
|
============================================================================
|
|
/*$FreeBSD$*/
|
|
|
|
November 12, 2010
|
|
|
|
|
|
Contents
|
|
========
|
|
|
|
- Overview
|
|
- Supported Adapters
|
|
- Building and Installation
|
|
- Additional Configurations and Tuning
|
|
- Known Limitations
|
|
|
|
|
|
Overview
|
|
========
|
|
|
|
This file describes the FreeBSD* driver for the Intel(R) Ethernet 10 Gigabit
|
|
Family of Adapters. Driver has been developed for use with FreeBSD 7.2 or later.
|
|
|
|
For questions related to hardware requirements, refer to the documentation
|
|
supplied with your Intel 10GbE adapter. All hardware requirements listed
|
|
apply to use with FreeBSD.
|
|
|
|
|
|
Supported Adapters
|
|
==================
|
|
|
|
The driver in this release is compatible with 82598 and 82599-based Intel
|
|
Network Connections.
|
|
|
|
SFP+ Devices with Pluggable Optics
|
|
----------------------------------
|
|
|
|
82599-BASED ADAPTERS
|
|
|
|
NOTE: If your 82599-based Intel(R) Ethernet Network Adapter came with Intel
|
|
optics, or is an Intel(R) Ethernet Server Adapter X520-2, then it only supports
|
|
Intel optics and/or the direct attach cables listed below.
|
|
|
|
When 82599-based SFP+ devices are connected back to back, they should be set to
|
|
the same Speed setting via Ethtool. Results may vary if you mix speed settings.
|
|
|
|
Supplier Type Part Numbers
|
|
|
|
SR Modules
|
|
Intel DUAL RATE 1G/10G SFP+ SR (bailed) FTLX8571D3BCV-IT
|
|
Intel DUAL RATE 1G/10G SFP+ SR (bailed) AFBR-703SDZ-IN2
|
|
Intel DUAL RATE 1G/10G SFP+ SR (bailed) AFBR-703SDDZ-IN1
|
|
LR Modules
|
|
Intel DUAL RATE 1G/10G SFP+ LR (bailed) FTLX1471D3BCV-IT
|
|
Intel DUAL RATE 1G/10G SFP+ LR (bailed) AFCT-701SDZ-IN2
|
|
Intel DUAL RATE 1G/10G SFP+ LR (bailed) AFCT-701SDDZ-IN1
|
|
|
|
The following is a list of 3rd party SFP+ modules and direct attach cables that
|
|
have received some testing. Not all modules are applicable to all devices.
|
|
|
|
Supplier Type Part Numbers
|
|
|
|
Finisar SFP+ SR bailed, 10g single rate FTLX8571D3BCL
|
|
Avago SFP+ SR bailed, 10g single rate AFBR-700SDZ
|
|
Finisar SFP+ LR bailed, 10g single rate FTLX8571D3BCV-IT
|
|
|
|
Finisar DUAL RATE 1G/10G SFP+ SR (No Bail) FTLX8571D3QCV-IT
|
|
Avago DUAL RATE 1G/10G SFP+ SR (No Bail) AFBR-703SDZ-IN1
|
|
Finisar DUAL RATE 1G/10G SFP+ LR (No Bail) FTLX1471D3QCV-IT
|
|
Avago DUAL RATE 1G/10G SFP+ LR (No Bail) AFCT-701SDZ-IN1
|
|
Finistar 1000BASE-T SFP FCLF8522P2BTL
|
|
Avago 1000BASE-T SFP ABCU-5710RZ
|
|
|
|
82599-based adapters support all passive and active limiting direct attach
|
|
cables that comply with SFF-8431 v4.1 and SFF-8472 v10.4 specifications.
|
|
|
|
Laser turns off for SFP+ when ifconfig down
|
|
--------------------------------------------------------
|
|
"ifconfig down" turns off the laser for 82599-based SFP+ fiber adapters.
|
|
"ifconfig up" turns on the later.
|
|
|
|
82598-BASED ADAPTERS
|
|
|
|
NOTES for 82598-Based Adapters:
|
|
- Intel(R) Ethernet Network Adapters that support removable optical modules
|
|
only support their original module type (i.e., the Intel(R) 10 Gigabit SR
|
|
Dual Port Express Module only supports SR optical modules). If you plug
|
|
in a different type of module, the driver will not load.
|
|
- Hot Swapping/hot plugging optical modules is not supported.
|
|
- Only single speed, 10 gigabit modules are supported.
|
|
- LAN on Motherboard (LOMs) may support DA, SR, or LR modules. Other module
|
|
types are not supported. Please see your system documentation for details.
|
|
|
|
The following is a list of 3rd party SFP+ modules and direct attach cables that have
|
|
received some testing. Not all modules are applicable to all devices.
|
|
|
|
Supplier Type Part Numbers
|
|
|
|
Finisar SFP+ SR bailed, 10g single rate FTLX8571D3BCL
|
|
Avago SFP+ SR bailed, 10g single rate AFBR-700SDZ
|
|
Finisar SFP+ LR bailed, 10g single rate FTLX1471D3BCL
|
|
|
|
82598-based adapters support all passive direct attach cables that comply
|
|
with SFF-8431 v4.1 and SFF-8472 v10.4 specifications. Active direct attach
|
|
cables are not supported.
|
|
|
|
Third party optic modules and cables referred to above are listed only for the
|
|
purpose of highlighting third party specifications and potential compatibility,
|
|
and are not recommendations or endorsements or sponsorship of any third party's
|
|
product by Intel. Intel is not endorsing or promoting products made by any
|
|
third party and the third party reference is provided only to share information
|
|
regarding certain optic modules and cables with the above specifications. There
|
|
may be other manufacturers or suppliers, producing or supplying optic modules
|
|
and cables with similar or matching descriptions. Customers must use their own
|
|
discretion and diligence to purchase optic modules and cables from any third
|
|
party of their choice. Customer are solely responsible for assessing the
|
|
suitability of the product and/or devices and for the selection of the vendor
|
|
for purchasing any product. INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL
|
|
DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF
|
|
SUCH THIRD PARTY PRODUCTS OR SELECTION OF VENDOR BY CUSTOMERS.
|
|
|
|
Configuration and Tuning
|
|
========================
|
|
|
|
The driver supports Transmit/Receive Checksum Offload and Jumbo Frames on
|
|
all 10 Gigabit adapters.
|
|
|
|
Jumbo Frames
|
|
------------
|
|
To enable Jumbo Frames, use the ifconfig utility to increase the MTU
|
|
beyond 1500 bytes.
|
|
|
|
NOTES:
|
|
|
|
- The Jumbo Frames setting on the switch must be set to at least
|
|
22 bytes larger than that of the adapter.
|
|
|
|
- There are known performance issues with this driver when running
|
|
UDP traffic with Jumbo Frames.
|
|
|
|
The Jumbo Frames MTU range for Intel Adapters is 1500 to 16114. The default
|
|
MTU range is 1500. To modify the setting, enter the following:
|
|
|
|
ifconfig ix<interface_num> <hostname or IP address> mtu 9000
|
|
|
|
To confirm an interface's MTU value, use the ifconfig command. To confirm
|
|
the MTU used between two specific devices, use:
|
|
|
|
route get <destination_IP_address>
|
|
|
|
VLANs
|
|
-----
|
|
To create a new VLAN pseudo-interface:
|
|
|
|
ifconfig <vlan_name> create
|
|
|
|
To associate the VLAN pseudo-interface with a physical interface and
|
|
assign a VLAN ID, IP address, and netmask:
|
|
|
|
ifconfig <vlan_name> <ip_address> netmask <subnet_mask> vlan
|
|
<vlan_id> vlandev <physical_interface>
|
|
|
|
Example:
|
|
|
|
ifconfig vlan10 10.0.0.1 netmask 255.255.255.0 vlan 10 vlandev ixgbe0
|
|
|
|
In this example, all packets will be marked on egress with 802.1Q VLAN
|
|
tags, specifying a VLAN ID of 10.
|
|
|
|
To remove a VLAN pseudo-interface:
|
|
|
|
ifconfig <vlan_name> destroy
|
|
|
|
|
|
Checksum Offload
|
|
----------------
|
|
|
|
Checksum offloading supports both TCP and UDP packets and is
|
|
supported for both transmit and receive.
|
|
|
|
Checksum offloading can be enabled or disabled using ifconfig.
|
|
Both transmit and receive offloading will be either enabled or
|
|
disabled together. You cannot enable/disable one without the other.
|
|
|
|
To enable checksum offloading:
|
|
|
|
ifconfig <interface_num> rxcsum
|
|
|
|
To disable checksum offloading:
|
|
|
|
ifconfig <interface_num> -rxcsum
|
|
|
|
To confirm the current setting:
|
|
|
|
ifconfig <interface_num>
|
|
|
|
|
|
TSO
|
|
---
|
|
|
|
TSO is enabled by default.
|
|
|
|
To disable:
|
|
|
|
ifconfig <interface_num> -tso
|
|
|
|
To re-enable:
|
|
|
|
ifconfig <interface_num> tso
|
|
|
|
LRO
|
|
---
|
|
|
|
Large Receive Offload is available in the driver; it is on by default.
|
|
It can be disabled by using:
|
|
ifconfig <interface_num> -lro
|
|
To enable:
|
|
ifconfig <interface_num> lro
|
|
|
|
|
|
Important system configuration changes:
|
|
---------------------------------------
|
|
|
|
When there is a choice run on a 64bit OS rather than 32, it makes a
|
|
significant difference in improvement.
|
|
|
|
The default scheduler SCHED_4BSD is not smart about SMP locality issues.
|
|
Significant improvement can be achieved by switching to the ULE scheduler.
|
|
|
|
This is done by changing the entry in the config file from SCHED_4BSD to
|
|
SCHED_ULE. Note that this is only advisable on FreeBSD 7, on 6.X there have
|
|
been stability problems with ULE.
|
|
|
|
The interface can generate high number of interrupts. To avoid running
|
|
into the limit set by the kernel, adjust hw.intr_storm_threshold
|
|
setting using sysctl:
|
|
|
|
sysctl hw.intr_storm_threshold=9000 (the default is 1000)
|
|
|
|
For this change to take effect on boot, edit /etc/sysctl.conf and add the
|
|
line:
|
|
hw.intr_storm_threshold=9000
|
|
|
|
If you still see Interrupt Storm detected messages, increase the limit to a
|
|
higher number.
|
|
|
|
Best throughput results are seen with a large MTU; use 9000 if possible.
|
|
|
|
The default number of descriptors is 1024, increasing this to 2K or even
|
|
4K may improve performance in some workloads, but change carefully.
|
|
|
|
|
|
Known Limitations
|
|
=================
|
|
|
|
For known hardware and troubleshooting issues, refer to the following website.
|
|
|
|
http://support.intel.com/support/go/network/adapter/home.htm
|
|
|
|
Either select the link for your adapter or perform a search for the adapter
|
|
number. The adapter's page lists many issues. For a complete list of hardware
|
|
issues download your adapter's user guide and read the Release Notes.
|
|
|
|
UDP stress test with 10GbE driver
|
|
---------------------------------
|
|
Under small packets UDP stress test with 10GbE driver, the FreeBSD system
|
|
will drop UDP packets due to the fullness of socket buffers. You may want
|
|
to change the driver's Flow Control variables to the minimum value for
|
|
controlling packet reception.
|
|
|
|
Attempting to configure larger MTUs with a large numbers of processors may
|
|
generate the error message "ix0:could not setup receive structures"
|
|
--------------------------------------------------------------------------
|
|
When using the ixgbe driver with RSS autoconfigured based on the number of
|
|
cores (the default setting) and that number is larger than 4, increase the
|
|
memory resources allocated for the mbuf pool as follows:
|
|
|
|
Add to the sysctl.conf file for the system:
|
|
|
|
kern.ipc.nmbclusters=262144
|
|
kern.ipc.nmbjumbop=262144
|
|
|
|
Lower than expected performance on dual port 10GbE devices
|
|
----------------------------------------------------------
|
|
Some PCI-E x8 slots are actually configured as x4 slots. These slots have
|
|
insufficient bandwidth for full 10Gbe line rate with dual port 10GbE devices.
|
|
The driver can detect this situation and will write the following message in
|
|
the system log: "PCI-Express bandwidth available for this card is not
|
|
sufficient for optimal performance. For optimal performance a x8 PCI-Express
|
|
slot is required."
|
|
|
|
If this error occurs, moving your adapter to a true x8 slot will resolve the
|
|
issue.
|
|
|
|
|
|
|
|
Support
|
|
=======
|
|
|
|
For general information and support, go to the Intel support website at:
|
|
|
|
www.intel.com/support/
|
|
|
|
If an issue is identified with the released source code on the supported
|
|
kernel with a supported adapter, email the specific information related to
|
|
the issue to freebsd@intel.com
|
|
|
|
|
|
|
|
License
|
|
=======
|
|
|
|
This software program is released under the terms of a license agreement
|
|
between you ('Licensee') and Intel. Do not use or load this software or any
|
|
associated materials (collectively, the 'Software') until you have carefully
|
|
read the full terms and conditions of the LICENSE located in this software
|
|
package. By loading or using the Software, you agree to the terms of this
|
|
Agreement. If you do not agree with the terms of this Agreement, do not
|
|
install or use the Software.
|
|
|
|
* Other names and brands may be claimed as the property of others.
|
|
|
|
|