mirror of
https://git.FreeBSD.org/src.git
synced 2024-12-21 11:13:30 +00:00
fd75b91d13
(which should be a PCIE Gen 3 slot for this adapter) by looking back thru the PCI parent devices to the slot device. The fix above also corrects the bandwidth display to GT/s rather than the incorrect Gb/s Next, allow the use of ALTQ if you select the compile option IXGBE_LEGACY_TX. Allow the use of 'unsupported' optic modules by a compile option as well. Add a phy reset capability into the stop code, this is so a static configured driver will still behave properly when taken down (not being able to unload it). This revision synchronizes the shared code with Intel internal current code, and note that it now includes DCB supporting code, this was necessitated by some internal changes with the code, but it also will provide the opportunity to develop this feature in the core driver down the road. I have edited the README to get rid of some of the worse anachronisms in it as well, its by no means as robust as I might wish at this point however. Oh, I also have included some conditional stuff in the code so it will be compatible in both the 9.X and 10 environments. Performance has been a focus in recent changes and I believe this revision driver will perform very well in most workloads. MFC after: 2 weeks
320 lines
12 KiB
Plaintext
320 lines
12 KiB
Plaintext
FreeBSD Driver for Intel(R) Ethernet 10 Gigabit PCI Express Server Adapters
|
|
============================================================================
|
|
/*$FreeBSD$*/
|
|
|
|
Jun 18, 2013
|
|
|
|
|
|
Contents
|
|
========
|
|
|
|
- Overview
|
|
- Supported Adapters
|
|
- Building and Installation
|
|
- Additional Configurations and Tuning
|
|
- Known Limitations
|
|
|
|
|
|
Overview
|
|
========
|
|
|
|
This file describes the FreeBSD* driver for the
|
|
Intel(R) Ethernet 10 Gigabit Family of Adapters.
|
|
|
|
For questions related to hardware requirements, refer to the documentation
|
|
supplied with your Intel 10GbE adapter. All hardware requirements listed
|
|
apply to use with FreeBSD.
|
|
|
|
|
|
Supported Adapters
|
|
==================
|
|
|
|
The driver in this release is compatible with 82598 and 82599-based Intel
|
|
Network Connections.
|
|
|
|
SFP+ Devices with Pluggable Optics
|
|
----------------------------------
|
|
|
|
82599-BASED ADAPTERS
|
|
|
|
NOTE: If your 82599-based Intel(R) Ethernet Network Adapter came with Intel
|
|
optics, or is an Intel(R) Ethernet Server Adapter X520-2, then it only supports
|
|
Intel optics and/or the direct attach cables listed below.
|
|
|
|
When 82599-based SFP+ devices are connected back to back, they should be set to
|
|
the same Speed setting. Results may vary if you mix speed settings.
|
|
|
|
Supplier Type Part Numbers
|
|
|
|
SR Modules
|
|
Intel DUAL RATE 1G/10G SFP+ SR (bailed) FTLX8571D3BCV-IT
|
|
Intel DUAL RATE 1G/10G SFP+ SR (bailed) AFBR-703SDZ-IN2
|
|
Intel DUAL RATE 1G/10G SFP+ SR (bailed) AFBR-703SDDZ-IN1
|
|
LR Modules
|
|
Intel DUAL RATE 1G/10G SFP+ LR (bailed) FTLX1471D3BCV-IT
|
|
Intel DUAL RATE 1G/10G SFP+ LR (bailed) AFCT-701SDZ-IN2
|
|
Intel DUAL RATE 1G/10G SFP+ LR (bailed) AFCT-701SDDZ-IN1
|
|
|
|
The following is a list of 3rd party SFP+ modules and direct attach cables that
|
|
have received some testing. Not all modules are applicable to all devices.
|
|
|
|
Supplier Type Part Numbers
|
|
|
|
Finisar SFP+ SR bailed, 10g single rate FTLX8571D3BCL
|
|
Avago SFP+ SR bailed, 10g single rate AFBR-700SDZ
|
|
Finisar SFP+ LR bailed, 10g single rate FTLX8571D3BCV-IT
|
|
|
|
Finisar DUAL RATE 1G/10G SFP+ SR (No Bail) FTLX8571D3QCV-IT
|
|
Avago DUAL RATE 1G/10G SFP+ SR (No Bail) AFBR-703SDZ-IN1
|
|
Finisar DUAL RATE 1G/10G SFP+ LR (No Bail) FTLX1471D3QCV-IT
|
|
Avago DUAL RATE 1G/10G SFP+ LR (No Bail) AFCT-701SDZ-IN1
|
|
Finistar 1000BASE-T SFP FCLF8522P2BTL
|
|
Avago 1000BASE-T SFP ABCU-5710RZ
|
|
|
|
NOTE: As of driver version 2.5.13 it is possible to allow the operation
|
|
of unsupported modules by setting the static variable 'allow_unsupported_sfp'
|
|
to TRUE and rebuilding the driver. If problems occur please assure that they
|
|
can be reproduced with fully supported optics first.
|
|
|
|
82599-based adapters support all passive and active limiting direct attach
|
|
cables that comply with SFF-8431 v4.1 and SFF-8472 v10.4 specifications.
|
|
|
|
Laser turns off for SFP+ when ifconfig down
|
|
--------------------------------------------------------
|
|
"ifconfig down" turns off the laser for 82599-based SFP+ fiber adapters.
|
|
"ifconfig up" turns on the later.
|
|
|
|
82598-BASED ADAPTERS
|
|
|
|
NOTES for 82598-Based Adapters:
|
|
- Intel(R) Ethernet Network Adapters that support removable optical modules
|
|
only support their original module type (i.e., the Intel(R) 10 Gigabit SR
|
|
Dual Port Express Module only supports SR optical modules). If you plug
|
|
in a different type of module, the driver will not load.
|
|
- Hot Swapping/hot plugging optical modules is not supported.
|
|
- Only single speed, 10 gigabit modules are supported.
|
|
- LAN on Motherboard (LOMs) may support DA, SR, or LR modules. Other module
|
|
types are not supported. Please see your system documentation for details.
|
|
|
|
The following is a list of 3rd party SFP+ modules and direct attach cables that have
|
|
received some testing. Not all modules are applicable to all devices.
|
|
|
|
Supplier Type Part Numbers
|
|
|
|
Finisar SFP+ SR bailed, 10g single rate FTLX8571D3BCL
|
|
Avago SFP+ SR bailed, 10g single rate AFBR-700SDZ
|
|
Finisar SFP+ LR bailed, 10g single rate FTLX1471D3BCL
|
|
|
|
82598-based adapters support all passive direct attach cables that comply
|
|
with SFF-8431 v4.1 and SFF-8472 v10.4 specifications. Active direct attach
|
|
cables are not supported.
|
|
|
|
Third party optic modules and cables referred to above are listed only for the
|
|
purpose of highlighting third party specifications and potential compatibility,
|
|
and are not recommendations or endorsements or sponsorship of any third party's
|
|
product by Intel. Intel is not endorsing or promoting products made by any
|
|
third party and the third party reference is provided only to share information
|
|
regarding certain optic modules and cables with the above specifications. There
|
|
may be other manufacturers or suppliers, producing or supplying optic modules
|
|
and cables with similar or matching descriptions. Customers must use their own
|
|
discretion and diligence to purchase optic modules and cables from any third
|
|
party of their choice. Customer are solely responsible for assessing the
|
|
suitability of the product and/or devices and for the selection of the vendor
|
|
for purchasing any product. INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL
|
|
DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF
|
|
SUCH THIRD PARTY PRODUCTS OR SELECTION OF VENDOR BY CUSTOMERS.
|
|
|
|
Configuration and Tuning
|
|
========================
|
|
|
|
The driver supports Transmit/Receive Checksum Offload and Jumbo Frames on
|
|
all 10 Gigabit adapters.
|
|
|
|
Jumbo Frames
|
|
------------
|
|
To enable Jumbo Frames, use the ifconfig utility to increase the MTU
|
|
beyond 1500 bytes.
|
|
|
|
NOTES:
|
|
|
|
- The Jumbo Frames setting on the switch must be set to at least
|
|
22 bytes larger than that of the adapter.
|
|
|
|
- There are known performance issues with this driver when running
|
|
UDP traffic with Jumbo Frames.
|
|
|
|
The Jumbo Frames MTU range for Intel Adapters is 1500 to 16114. The default
|
|
MTU range is 1500. To modify the setting, enter the following:
|
|
|
|
ifconfig ix<interface_num> <hostname or IP address> mtu 9000
|
|
|
|
To confirm an interface's MTU value, use the ifconfig command. To confirm
|
|
the MTU used between two specific devices, use:
|
|
|
|
route get <destination_IP_address>
|
|
|
|
VLANs
|
|
-----
|
|
To create a new VLAN pseudo-interface:
|
|
|
|
ifconfig <vlan_name> create
|
|
|
|
To associate the VLAN pseudo-interface with a physical interface and
|
|
assign a VLAN ID, IP address, and netmask:
|
|
|
|
ifconfig <vlan_name> <ip_address> netmask <subnet_mask> vlan
|
|
<vlan_id> vlandev <physical_interface>
|
|
|
|
Example:
|
|
|
|
ifconfig vlan10 10.0.0.1 netmask 255.255.255.0 vlan 10 vlandev ixgbe0
|
|
|
|
In this example, all packets will be marked on egress with 802.1Q VLAN
|
|
tags, specifying a VLAN ID of 10.
|
|
|
|
To remove a VLAN pseudo-interface:
|
|
|
|
ifconfig <vlan_name> destroy
|
|
|
|
|
|
Checksum Offload
|
|
----------------
|
|
|
|
Checksum offloading supports both TCP and UDP packets and is
|
|
supported for both transmit and receive.
|
|
|
|
Checksum offloading can be enabled or disabled using ifconfig.
|
|
Both transmit and receive offloading will be either enabled or
|
|
disabled together. You cannot enable/disable one without the other.
|
|
|
|
To enable checksum offloading:
|
|
|
|
ifconfig <interface_num> rxcsum
|
|
|
|
To disable checksum offloading:
|
|
|
|
ifconfig <interface_num> -rxcsum
|
|
|
|
To confirm the current setting:
|
|
|
|
ifconfig <interface_num>
|
|
|
|
|
|
TSO
|
|
---
|
|
|
|
TSO is enabled by default.
|
|
|
|
To disable:
|
|
|
|
ifconfig <interface_num> -tso
|
|
|
|
To re-enable:
|
|
|
|
ifconfig <interface_num> tso
|
|
|
|
LRO
|
|
---
|
|
|
|
Large Receive Offload is available in the driver; it is on by default.
|
|
It can be disabled by using:
|
|
ifconfig <interface_num> -lro
|
|
To enable:
|
|
ifconfig <interface_num> lro
|
|
|
|
|
|
Important system configuration changes:
|
|
---------------------------------------
|
|
|
|
When there is a choice run on a 64bit OS rather than 32, it makes a
|
|
significant difference in improvement.
|
|
|
|
The interface can generate a high number of interrupts. To avoid running
|
|
into the limit set by the kernel, adjust hw.intr_storm_threshold
|
|
setting using sysctl:
|
|
|
|
sysctl hw.intr_storm_threshold=9000 (the default is 1000)
|
|
|
|
For this change to take effect on boot, edit /etc/sysctl.conf and add the
|
|
line:
|
|
hw.intr_storm_threshold=9000
|
|
|
|
If you still see Interrupt Storm detected messages, increase the limit to a
|
|
higher number, or the detection can be disabled by setting it to 0.
|
|
|
|
The default number of descriptors is 2048, increasing or descreasing
|
|
may improve performance in some workloads, but change carefully.
|
|
|
|
|
|
Known Limitations
|
|
=================
|
|
|
|
For known hardware and troubleshooting issues, refer to the following website.
|
|
|
|
http://support.intel.com/support/go/network/adapter/home.htm
|
|
|
|
Either select the link for your adapter or perform a search for the adapter
|
|
number. The adapter's page lists many issues. For a complete list of hardware
|
|
issues download your adapter's user guide and read the Release Notes.
|
|
|
|
UDP stress test with 10GbE driver
|
|
---------------------------------
|
|
Under small packets UDP stress test with 10GbE driver, the FreeBSD system
|
|
will drop UDP packets due to the fullness of socket buffers. You may want
|
|
to change the driver's Flow Control variables to the minimum value for
|
|
controlling packet reception.
|
|
|
|
Attempting to configure larger MTUs with a large numbers of processors may
|
|
generate the error message "ix0:could not setup receive structures"
|
|
--------------------------------------------------------------------------
|
|
When using the ixgbe driver with RSS autoconfigured based on the number of
|
|
cores (the default setting) and that number is larger than 4, increase the
|
|
memory resources allocated for the mbuf pool as follows:
|
|
|
|
Add to the sysctl.conf file for the system:
|
|
|
|
kern.ipc.nmbclusters=262144
|
|
kern.ipc.nmbjumbop=262144
|
|
|
|
Lower than expected performance on dual port 10GbE devices
|
|
----------------------------------------------------------
|
|
Some PCI-E x8 slots are actually configured as x4 slots. These slots have
|
|
insufficient bandwidth for full 10Gbe line rate with dual port 10GbE devices.
|
|
The driver will detect this situation and will write the following message in
|
|
the system log: "PCI-Express bandwidth available for this card is not
|
|
sufficient for optimal performance. For optimal performance a x8 PCI-Express
|
|
slot is required."
|
|
|
|
If this error occurs, moving your adapter to a true x8 slot will resolve the
|
|
issue.
|
|
|
|
|
|
|
|
Support
|
|
=======
|
|
|
|
For general information and support, go to the Intel support website at:
|
|
|
|
www.intel.com/support/
|
|
|
|
If an issue is identified with the released source code on the supported
|
|
kernel with a supported adapter, email the specific information related to
|
|
the issue to freebsd@intel.com
|
|
|
|
|
|
|
|
License
|
|
=======
|
|
|
|
This software program is released under the terms of a license agreement
|
|
between you ('Licensee') and Intel. Do not use or load this software or any
|
|
associated materials (collectively, the 'Software') until you have carefully
|
|
read the full terms and conditions of the LICENSE located in this software
|
|
package. By loading or using the Software, you agree to the terms of this
|
|
Agreement. If you do not agree with the terms of this Agreement, do not
|
|
install or use the Software.
|
|
|
|
* Other names and brands may be claimed as the property of others.
|
|
|
|
|