mirror of
https://git.FreeBSD.org/src.git
synced 2024-12-23 11:18:54 +00:00
12c3456003
Add macro EVL_APPLY_VLID() which may be used to apply an 802.1q VLAN ID to the M_VLANTAG field in an mbuf packet header non-destructively. This will be used by net80211 to begin with. Add macro EVL_APPLY_PRI() which may be used to apply an 802.1p priority class to the M_VLANTAG field in an mbuf packet header non-destructively. Add other macros for manipulating tags and the CFI bit. Submitted by: Boris Kovalenko (EVL_CFIOFTAG(), EVL_MAKETAG())
138 lines
4.6 KiB
C
138 lines
4.6 KiB
C
/*-
|
|
* Copyright 1998 Massachusetts Institute of Technology
|
|
*
|
|
* Permission to use, copy, modify, and distribute this software and
|
|
* its documentation for any purpose and without fee is hereby
|
|
* granted, provided that both the above copyright notice and this
|
|
* permission notice appear in all copies, that both the above
|
|
* copyright notice and this permission notice appear in all
|
|
* supporting documentation, and that the name of M.I.T. not be used
|
|
* in advertising or publicity pertaining to distribution of the
|
|
* software without specific, written prior permission. M.I.T. makes
|
|
* no representations about the suitability of this software for any
|
|
* purpose. It is provided "as is" without express or implied
|
|
* warranty.
|
|
*
|
|
* THIS SOFTWARE IS PROVIDED BY M.I.T. ``AS IS''. M.I.T. DISCLAIMS
|
|
* ALL EXPRESS OR IMPLIED WARRANTIES WITH REGARD TO THIS SOFTWARE,
|
|
* INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
|
|
* MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT
|
|
* SHALL M.I.T. BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
|
|
* SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
|
|
* LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF
|
|
* USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND
|
|
* ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY,
|
|
* OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT
|
|
* OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
|
|
* SUCH DAMAGE.
|
|
*
|
|
* $FreeBSD$
|
|
*/
|
|
|
|
#ifndef _NET_IF_VLAN_VAR_H_
|
|
#define _NET_IF_VLAN_VAR_H_ 1
|
|
|
|
struct ether_vlan_header {
|
|
u_char evl_dhost[ETHER_ADDR_LEN];
|
|
u_char evl_shost[ETHER_ADDR_LEN];
|
|
u_int16_t evl_encap_proto;
|
|
u_int16_t evl_tag;
|
|
u_int16_t evl_proto;
|
|
};
|
|
|
|
#define EVL_VLID_MASK 0x0FFF
|
|
#define EVL_PRI_MASK 0xE000
|
|
#define EVL_VLANOFTAG(tag) ((tag) & EVL_VLID_MASK)
|
|
#define EVL_PRIOFTAG(tag) (((tag) >> 13) & 7)
|
|
#define EVL_CFIOFTAG(tag) (((tag) >> 12) & 1)
|
|
#define EVL_MAKETAG(vlid, pri, cfi) \
|
|
((((((pri) & 7) << 1) | ((cfi) & 1)) << 12) | ((vlid) & EVL_VLID_MASK))
|
|
|
|
/* Set the VLAN ID in an mbuf packet header non-destructively. */
|
|
#define EVL_APPLY_VLID(m, vlid) \
|
|
do { \
|
|
if ((m)->m_flags & M_VLANTAG) { \
|
|
(m)->m_pkthdr.ether_vtag &= EVL_VLID_MASK; \
|
|
(m)->m_pkthdr.ether_vtag |= (vlid); \
|
|
} else { \
|
|
(m)->m_pkthdr.ether_vtag = (vlid); \
|
|
(m)->m_flags |= M_VLANTAG; \
|
|
} \
|
|
} while (0)
|
|
|
|
/* Set the priority ID in an mbuf packet header non-destructively. */
|
|
#define EVL_APPLY_PRI(m, pri) \
|
|
do { \
|
|
if ((m)->m_flags & M_VLANTAG) { \
|
|
uint16_t __vlantag = (m)->m_pkthdr.ether_vtag; \
|
|
(m)->m_pkthdr.ether_vtag |= EVL_MAKETAG( \
|
|
EVL_VLANOFTAG(__vlantag), (pri), \
|
|
EVL_CFIOFTAG(__vlantag)); \
|
|
} else { \
|
|
(m)->m_pkthdr.ether_vtag = \
|
|
EVL_MAKETAG(0, (pri), 0); \
|
|
(m)->m_flags |= M_VLANTAG; \
|
|
} \
|
|
} while (0)
|
|
|
|
/* sysctl(3) tags, for compatibility purposes */
|
|
#define VLANCTL_PROTO 1
|
|
#define VLANCTL_MAX 2
|
|
|
|
/*
|
|
* Configuration structure for SIOCSETVLAN and SIOCGETVLAN ioctls.
|
|
*/
|
|
struct vlanreq {
|
|
char vlr_parent[IFNAMSIZ];
|
|
u_short vlr_tag;
|
|
};
|
|
#define SIOCSETVLAN SIOCSIFGENERIC
|
|
#define SIOCGETVLAN SIOCGIFGENERIC
|
|
|
|
#ifdef _KERNEL
|
|
/*
|
|
* Drivers that are capable of adding and removing the VLAN header
|
|
* in hardware indicate they support this by marking IFCAP_VLAN_HWTAGGING
|
|
* in if_capabilities. Drivers for hardware that is capable
|
|
* of handling larger MTU's that may include a software-appended
|
|
* VLAN header w/o lowering the normal MTU should mark IFCAP_VLAN_MTU
|
|
* in if_capabilities; this notifies the VLAN code it can leave the
|
|
* MTU on the vlan interface at the normal setting.
|
|
*/
|
|
|
|
/*
|
|
* VLAN tags are stored in host byte order. Byte swapping may be
|
|
* necessary.
|
|
*
|
|
* Drivers that support hardware VLAN tag stripping fill in the
|
|
* received VLAN tag (containing both vlan and priority information)
|
|
* into the ether_vtag mbuf packet header field:
|
|
*
|
|
* m->m_pkthdr.ether_vtag = vlan_id; // ntohs()?
|
|
* m->m_flags |= M_VLANTAG;
|
|
*
|
|
* to mark the packet m with the specified VLAN tag.
|
|
*
|
|
* On output the driver should check the mbuf for the M_VLANTAG
|
|
* flag to see if a VLAN tag is present and valid:
|
|
*
|
|
* if (m->m_flags & M_VLANTAG) {
|
|
* ... = m->m_pkthdr.ether_vtag; // htons()?
|
|
* ... pass tag to hardware ...
|
|
* }
|
|
*
|
|
* Note that a driver must indicate it supports hardware VLAN
|
|
* stripping/insertion by marking IFCAP_VLAN_HWTAGGING in
|
|
* if_capabilities.
|
|
*/
|
|
|
|
#define VLAN_CAPABILITIES(_ifp) do { \
|
|
if ((_ifp)->if_vlantrunk != NULL) \
|
|
(*vlan_trunk_cap_p)(_ifp); \
|
|
} while (0)
|
|
|
|
extern void (*vlan_trunk_cap_p)(struct ifnet *);
|
|
#endif /* _KERNEL */
|
|
|
|
#endif /* _NET_IF_VLAN_VAR_H_ */
|