1
0
mirror of https://git.FreeBSD.org/src.git synced 2024-12-25 11:37:56 +00:00
freebsd/sys/dev/ppbus/ppb_msq.c
Nicolas Souchu 0f210c922b Port of ppbus standalone framework to the newbus system.
Note1: the correct interrupt level is invoked correctly for each driver.
       For this purpose, drivers request the bus before being able to
       call BUS_SETUP_INTR and BUS_TEARDOWN_INTR call is forced by the ppbus
       core when drivers release it. Thus, when BUS_SETUP_INTR is called
       at ppbus driver level, ppbus checks that the caller owns the
       bus and stores the interrupt handler cookie (in order to unregister
       it later).

       Printing is impossible while plip link is up is still TRUE.
       vpo (ZIP driver) and lpt are make in such a way that
       using the ZIP and printing concurrently is permitted is also TRUE.

Note2: specific chipset detection is not done by default. PPC_PROBE_CHIPSET
       is now needed to force chipset detection. If set, the flags 0x40
       still avoid detection at boot.

Port of the pcf(4) driver to the newbus system (was previously directly
connected to the rootbus and attached by a bogus pcf_isa_probe function).
2000-01-14 00:18:06 +00:00

338 lines
7.6 KiB
C

/*-
* Copyright (c) 1998, 1999 Nicolas Souchu
* All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions
* are met:
* 1. Redistributions of source code must retain the above copyright
* notice, this list of conditions and the following disclaimer.
* 2. Redistributions in binary form must reproduce the above copyright
* notice, this list of conditions and the following disclaimer in the
* documentation and/or other materials provided with the distribution.
*
* THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
* ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
* IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
* ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
* FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
* DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
* OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
* HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
* LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
* OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
* SUCH DAMAGE.
*
* $FreeBSD$
*
*/
#include <machine/stdarg.h>
#include <sys/param.h>
#include <sys/systm.h>
#include <sys/kernel.h>
#include <sys/bus.h>
#include <dev/ppbus/ppbconf.h>
#include <dev/ppbus/ppb_msq.h>
#include "ppbus_if.h"
/* msq index (see PPB_MAX_XFER)
* These are device modes
*/
#define COMPAT_MSQ 0x0
#define NIBBLE_MSQ 0x1
#define PS2_MSQ 0x2
#define EPP17_MSQ 0x3
#define EPP19_MSQ 0x4
#define ECP_MSQ 0x5
/*
* Device mode to submsq conversion
*/
static struct ppb_xfer *
mode2xfer(device_t bus, struct ppb_device *ppbdev, int opcode)
{
int index, epp;
struct ppb_xfer *table;
switch (opcode) {
case MS_OP_GET:
table = ppbdev->get_xfer;
break;
case MS_OP_PUT:
table = ppbdev->put_xfer;
break;
default:
panic("%s: unknown opcode (%d)", __FUNCTION__, opcode);
}
/* retrieve the device operating mode */
switch (ppb_get_mode(bus)) {
case PPB_COMPATIBLE:
index = COMPAT_MSQ;
break;
case PPB_NIBBLE:
index = NIBBLE_MSQ;
break;
case PPB_PS2:
index = PS2_MSQ;
break;
case PPB_EPP:
switch ((epp = ppb_get_epp_protocol(bus))) {
case EPP_1_7:
index = EPP17_MSQ;
break;
case EPP_1_9:
index = EPP19_MSQ;
break;
default:
panic("%s: unknown EPP protocol (0x%x)!", __FUNCTION__,
epp);
}
break;
case PPB_ECP:
index = ECP_MSQ;
break;
default:
panic("%s: unknown mode (%d)", __FUNCTION__, ppbdev->mode);
}
return (&table[index]);
}
/*
* ppb_MS_init()
*
* Initialize device dependent submicrosequence of the current mode
*
*/
int
ppb_MS_init(device_t bus, device_t dev, struct ppb_microseq *loop, int opcode)
{
struct ppb_device *ppbdev = (struct ppb_device *)device_get_ivars(dev);
struct ppb_xfer *xfer = mode2xfer(bus, ppbdev, opcode);
xfer->loop = loop;
return (0);
}
/*
* ppb_MS_exec()
*
* Execute any microsequence opcode - expensive
*
*/
int
ppb_MS_exec(device_t bus, device_t dev, int opcode, union ppb_insarg param1,
union ppb_insarg param2, union ppb_insarg param3, int *ret)
{
struct ppb_microseq msq[] = {
{ MS_UNKNOWN, { { MS_UNKNOWN }, { MS_UNKNOWN }, { MS_UNKNOWN } } },
MS_RET(0)
};
/* initialize the corresponding microseq */
msq[0].opcode = opcode;
msq[0].arg[0] = param1;
msq[0].arg[1] = param2;
msq[0].arg[2] = param3;
/* execute the microseq */
return (ppb_MS_microseq(bus, dev, msq, ret));
}
/*
* ppb_MS_loop()
*
* Execute a microseq loop
*
*/
int
ppb_MS_loop(device_t bus, device_t dev, struct ppb_microseq *prolog,
struct ppb_microseq *body, struct ppb_microseq *epilog,
int iter, int *ret)
{
struct ppb_microseq loop_microseq[] = {
MS_CALL(0), /* execute prolog */
MS_SET(MS_UNKNOWN), /* set size of transfer */
/* loop: */
MS_CALL(0), /* execute body */
MS_DBRA(-1 /* loop: */),
MS_CALL(0), /* execute epilog */
MS_RET(0)
};
/* initialize the structure */
loop_microseq[0].arg[0].p = (void *)prolog;
loop_microseq[1].arg[0].i = iter;
loop_microseq[2].arg[0].p = (void *)body;
loop_microseq[4].arg[0].p = (void *)epilog;
/* execute the loop */
return (ppb_MS_microseq(bus, dev, loop_microseq, ret));
}
/*
* ppb_MS_init_msq()
*
* Initialize a microsequence - see macros in ppb_msq.h
*
*/
int
ppb_MS_init_msq(struct ppb_microseq *msq, int nbparam, ...)
{
int i;
int param, ins, arg, type;
va_list p_list = 0;
va_start(p_list, nbparam);
for (i=0; i<nbparam; i++) {
/* retrieve the parameter descriptor */
param = va_arg(p_list, int);
ins = MS_INS(param);
arg = MS_ARG(param);
type = MS_TYP(param);
/* check the instruction position */
if (arg >= PPB_MS_MAXARGS)
panic("%s: parameter out of range (0x%x)!",
__FUNCTION__, param);
#if 0
printf("%s: param = %d, ins = %d, arg = %d, type = %d\n",
__FUNCTION__, param, ins, arg, type);
#endif
/* properly cast the parameter */
switch (type) {
case MS_TYP_INT:
msq[ins].arg[arg].i = va_arg(p_list, int);
break;
case MS_TYP_CHA:
msq[ins].arg[arg].i = (int)va_arg(p_list, char);
break;
case MS_TYP_PTR:
msq[ins].arg[arg].p = va_arg(p_list, void *);
break;
case MS_TYP_FUN:
msq[ins].arg[arg].f = va_arg(p_list, void *);
break;
default:
panic("%s: unknown parameter (0x%x)!", __FUNCTION__,
param);
}
}
return (0);
}
/*
* ppb_MS_microseq()
*
* Interprete a microsequence. Some microinstructions are executed at adapter
* level to avoid function call overhead between ppbus and the adapter
*/
int
ppb_MS_microseq(device_t bus, device_t dev, struct ppb_microseq *msq, int *ret)
{
struct ppb_data *ppb = (struct ppb_data *)device_get_softc(bus);
struct ppb_device *ppbdev = (struct ppb_device *)device_get_ivars(dev);
struct ppb_microseq *mi; /* current microinstruction */
int error;
struct ppb_xfer *xfer;
/* microsequence executed to initialize the transfer */
struct ppb_microseq initxfer[] = {
MS_PTR(MS_UNKNOWN), /* set ptr to buffer */
MS_SET(MS_UNKNOWN), /* set transfer size */
MS_RET(0)
};
if (ppb->ppb_owner != dev)
return (EACCES);
#define INCR_PC (mi ++)
mi = msq;
for (;;) {
switch (mi->opcode) {
case MS_OP_PUT:
case MS_OP_GET:
/* attempt to choose the best mode for the device */
xfer = mode2xfer(bus, ppbdev, mi->opcode);
/* figure out if we should use ieee1284 code */
if (!xfer->loop) {
if (mi->opcode == MS_OP_PUT) {
if ((error = PPBUS_WRITE(
device_get_parent(bus),
(char *)mi->arg[0].p,
mi->arg[1].i, 0)))
goto error;
INCR_PC;
goto next;
} else
panic("%s: IEEE1284 read not supported", __FUNCTION__);
}
/* XXX should use ppb_MS_init_msq() */
initxfer[0].arg[0].p = mi->arg[0].p;
initxfer[1].arg[0].i = mi->arg[1].i;
/* initialize transfer */
ppb_MS_microseq(bus, dev, initxfer, &error);
if (error)
goto error;
/* the xfer microsequence should not contain any
* MS_OP_PUT or MS_OP_GET!
*/
ppb_MS_microseq(bus, dev, xfer->loop, &error);
if (error)
goto error;
INCR_PC;
break;
case MS_OP_RET:
if (ret)
*ret = mi->arg[0].i; /* return code */
return (0);
break;
default:
/* executing microinstructions at ppc level is
* faster. This is the default if the microinstr
* is unknown here
*/
if ((error = PPBUS_EXEC_MICROSEQ(
device_get_parent(bus), &mi)))
goto error;
break;
}
next:
}
error:
return (error);
}