mirror of
https://git.FreeBSD.org/src.git
synced 2024-12-16 10:20:30 +00:00
a8e0b2e8ab
method of executing commands remotely. There are no rexec clients in the FreeBSD tree, and the client function rexec(3) is present only in libcompat. It has been documented as "obsolete" since 4.3BSD, and its use has been discouraged in the man page for over 10 years.
222 lines
5.1 KiB
Groff
222 lines
5.1 KiB
Groff
.\" Copyright (c) 1983, 1991, 1993
|
|
.\" The Regents of the University of California. All rights reserved.
|
|
.\"
|
|
.\" Redistribution and use in source and binary forms, with or without
|
|
.\" modification, are permitted provided that the following conditions
|
|
.\" are met:
|
|
.\" 1. Redistributions of source code must retain the above copyright
|
|
.\" notice, this list of conditions and the following disclaimer.
|
|
.\" 2. Redistributions in binary form must reproduce the above copyright
|
|
.\" notice, this list of conditions and the following disclaimer in the
|
|
.\" documentation and/or other materials provided with the distribution.
|
|
.\" 4. Neither the name of the University nor the names of its contributors
|
|
.\" may be used to endorse or promote products derived from this software
|
|
.\" without specific prior written permission.
|
|
.\"
|
|
.\" THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS ``AS IS'' AND
|
|
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
|
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
|
.\" ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE
|
|
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
|
|
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
|
|
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
|
|
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
|
|
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
|
|
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
|
|
.\" SUCH DAMAGE.
|
|
.\"
|
|
.\" @(#)rmt.8 8.3 (Berkeley) 6/1/94
|
|
.\" $FreeBSD$
|
|
.\"
|
|
.Dd June 1, 1994
|
|
.Dt RMT 8
|
|
.Os
|
|
.Sh NAME
|
|
.Nm rmt
|
|
.Nd remote magtape protocol module
|
|
.Sh SYNOPSIS
|
|
.Nm
|
|
.Sh DESCRIPTION
|
|
The
|
|
.Nm
|
|
utility is used by the remote dump and restore programs
|
|
in manipulating a magnetic tape drive through an interprocess
|
|
communication connection.
|
|
It is normally started up with an
|
|
.Xr rcmd 3
|
|
call.
|
|
.Pp
|
|
The
|
|
.Nm
|
|
utility accepts requests specific to the manipulation of
|
|
magnetic tapes, performs the commands, then responds with
|
|
a status indication.
|
|
All responses are in
|
|
.Tn ASCII
|
|
and in
|
|
one of two forms.
|
|
Successful commands have responses of:
|
|
.Bd -ragged -offset indent
|
|
.Sm off
|
|
.Sy A Ar number No \en
|
|
.Sm on
|
|
.Ed
|
|
.Pp
|
|
.Ar Number
|
|
is an
|
|
.Tn ASCII
|
|
representation of a decimal number.
|
|
Unsuccessful commands are responded to with:
|
|
.Bd -ragged -offset indent
|
|
.Sm off
|
|
.Xo Sy E Ar error-number
|
|
.No \en Ar error-message
|
|
.No \en
|
|
.Xc
|
|
.Sm on
|
|
.Ed
|
|
.Pp
|
|
.Ar Error-number
|
|
is one of the possible error
|
|
numbers described in
|
|
.Xr intro 2
|
|
and
|
|
.Ar error-message
|
|
is the corresponding error string as printed
|
|
from a call to
|
|
.Xr perror 3 .
|
|
The protocol is comprised of the
|
|
following commands, which are sent as indicated - no spaces are supplied
|
|
between the command and its arguments, or between its arguments, and
|
|
.Ql \en
|
|
indicates that a newline should be supplied:
|
|
.Bl -tag -width Ds
|
|
.Sm off
|
|
.It Xo Sy \&O Ar device
|
|
.No \en Ar mode No \en
|
|
.Xc
|
|
.Sm on
|
|
Open the specified
|
|
.Ar device
|
|
using the indicated
|
|
.Ar mode .
|
|
.Ar Device
|
|
is a full pathname and
|
|
.Ar mode
|
|
is an
|
|
.Tn ASCII
|
|
representation of a decimal
|
|
number suitable for passing to
|
|
.Xr open 2 .
|
|
If a device had already been opened, it is
|
|
closed before a new open is performed.
|
|
.Sm off
|
|
.It Xo Sy C Ar device No \en
|
|
.Xc
|
|
.Sm on
|
|
Close the currently open device.
|
|
The
|
|
.Ar device
|
|
specified is ignored.
|
|
.Sm off
|
|
.It Xo Sy L
|
|
.Ar whence No \en
|
|
.Ar offset No \en
|
|
.Xc
|
|
.Sm on
|
|
Perform an
|
|
.Xr lseek 2
|
|
operation using the specified parameters.
|
|
The response value is that returned from the
|
|
.Xr lseek 2
|
|
call.
|
|
.Sm off
|
|
.It Sy W Ar count No \en
|
|
.Sm on
|
|
Write data onto the open device.
|
|
The
|
|
.Nm
|
|
utility reads
|
|
.Ar count
|
|
bytes from the connection, aborting if
|
|
a premature end-of-file is encountered.
|
|
The response value is that returned from
|
|
the
|
|
.Xr write 2
|
|
call.
|
|
.Sm off
|
|
.It Sy R Ar count No \en
|
|
.Sm on
|
|
Read
|
|
.Ar count
|
|
bytes of data from the open device.
|
|
If
|
|
.Ar count
|
|
exceeds the size of the data buffer (10 kilobytes), it is
|
|
truncated to the data buffer size.
|
|
The
|
|
.Nm
|
|
utility then performs the requested
|
|
.Xr read 2
|
|
and responds with
|
|
.Sm off
|
|
.Sy A Ar count-read No \en
|
|
.Sm on
|
|
if the read was
|
|
successful; otherwise an error in the
|
|
standard format is returned.
|
|
If the read
|
|
was successful, the data read is then sent.
|
|
.Sm off
|
|
.It Xo Sy I Ar operation
|
|
.No \en Ar count No \en
|
|
.Xc
|
|
.Sm on
|
|
Perform a
|
|
.Dv MTIOCOP
|
|
.Xr ioctl 2
|
|
command using the specified parameters.
|
|
The parameters are interpreted as the
|
|
.Tn ASCII
|
|
representations of the decimal values
|
|
to place in the
|
|
.Ar mt_op
|
|
and
|
|
.Ar mt_count
|
|
fields of the structure used in the
|
|
.Xr ioctl 2
|
|
call.
|
|
The return value is the
|
|
.Ar count
|
|
parameter when the operation is successful.
|
|
.It Sy S
|
|
Return the status of the open device, as
|
|
obtained with a
|
|
.Dv MTIOCGET
|
|
.Xr ioctl 2
|
|
call.
|
|
If the operation was successful,
|
|
an ``ack'' is sent with the size of the
|
|
status buffer, then the status buffer is
|
|
sent (in binary).
|
|
.El
|
|
.Pp
|
|
Any other command causes
|
|
.Nm
|
|
to exit.
|
|
.Sh DIAGNOSTICS
|
|
All responses are of the form described above.
|
|
.Sh SEE ALSO
|
|
.Xr rcmd 3 ,
|
|
.Xr mtio 4 ,
|
|
.Xr rdump 8 ,
|
|
.Xr rrestore 8
|
|
.Sh HISTORY
|
|
The
|
|
.Nm
|
|
utility appeared in
|
|
.Bx 4.2 .
|
|
.Sh BUGS
|
|
People should be discouraged from using this for a remote
|
|
file access protocol.
|