Change definition of sflag
Reported-by: Johan Karlsson <k@numeri.campus.luth.se>
Doug <Doug@gorean.org>
green
World-broken-by: grog
Pointy-hat-passed-to: grog
isp_io_map, isp_no_fwload, isp_fwload, isp_no_nvram, isp_fcduplex
which are all bitmaps of isp instances that should or shouldn't
map memory space, I/O space, not load f/w, load f/w, ignore nvram,
not ignore nvarm, set full duplex mode. Also have an isp_seed value
that we can use to generate a pseudo seed for a synthetic WWN.
Other minor cosmetic cleanup. Add in support for the Qlogic ISP
2200. Very important change where we actually check now to see
whether we were successful in mapping request and response queues
(and fibre channel scratch space).
not having SCSI_ISP_SCCLUN config defined if we don't have f/w for
the 2200- it's resident firmware uses SCCLUN (65535 luns)). Change
the way the default LoopID is gathered (it's now a platform specific
define so that some attempt at a synthetic WWN can be made in case
NVRAM isn't readable).
Change initialization of options a bit- don't use ADISC. Set
FullDuplex mode if config options tells us to do so. Do not use
FULL_LOGIN after LIP- it's the right thing to do but it causes too
much loop disruption (Loop Resets). Sanity check some default
values. Redo construction of port and node WWNs based upon what we
have- if we have 2 in the top nibble, we can have distinct port
and node WWNs. Clean up some SCCLUN related code that we obviously
had never compiled (:-(). Audit commands coming int ispscsicmd and
don't throw commands at Fibre devices that do not have Class 3
service parameters TARGET ROLE defined.
Clean up f/w initialization a bit. Add Fabric support (or at least
the first blush of it). Whew - way too much to describe here.
Basically, after a LIP, hang out until we see a Loop Up or a Port
DataBase Change async event, then see if we're on a Fabric
(GET_PORT_NAME of FL_PORT_ID). If we are, try and scan the fabric
controller for fabric devices using the GetAllNext SNS subcommand.
As we find devices, announce them to the outer layer. Try and do
some guard code for broken (Brocade) SNS servers (that get stuck
in loops- gotta maybe do this a different way using the GP_ID3 cmd
instead). Then do a scan of the lower (local loop) ids using a
GET_PORT_NAME to see if the f/w has logged into anything at that
loop id. If so, then do a GET_PORT_DATABASE command. Do this scan
into a local database. At this point we can say the loop is 'Ready'.
After this, we merge our local loop port database with our stored
port database- in a as yet to be really fully exercised fashion we
try and follow the logic of something having moved around. The
first time we see something at a Loop ID, we fix it, for the purpose
of this system instance, at that Loop ID. If things shift around
so it ends up somewhere else, we still keep it at this Loop ID (our
'Target') but use the new (moved) Loop ID when we actually throw
commands at it. Check for insane cases of different Loop IDs both
claiming to have the same WWN- if that happens, invalidate both.
Notify the outer layer of devices that have arrived and devices
that have gone away. *Finally*, when this is done, search the
softc's database of Fabric devices and perform logout/login actions.
The Qlogic f/w maintains logout/login for all local loop devices.
We have to maintain logout/login for fabric devices- total PITA.
Expect to see this area undergo more change over time.
Change some fcp parameter structures such that we can get the portid
(24 bit value), get both node and port WWN, know whether we're on a fabric
or not, note whether we've ever seen the loop up, and note the current
state of the loop.
Replace the isp_pdb_t structure in fcparams with a reduced cost structure
that maintains a static relationship to 'Target', but can have the actual
loop ID used change (in case, post LIP, we discover things have moved
around). This also retains portid and node/port WWNs. This array gets
larger if we have fabric support compiled in.
Note special loop IDs that are invariate for this device- FL_PORT_ID
(0x7e) which tells us if there's a fabric controller present, FC_PORT_ID
and FC_SNS_ID (fabric controller port and fabric SNS server port). We don't
use the latter two for anything. IDs above FC_SNS_ID up through 255 are
available for mapping fabric devices to 'target' ids.
Add in a config define to set FC full duplex mode. Add in a define to
recognize the Qlogic 2200 boards. Add comments about ISPCTL commands.
Add and change some ISPASYNC enumes.
- The kernel environment variable 'hw.physmem' can be used to set the
amount of physical memory space, based at 0, that FreeBSD will use.
Any memory detected over this limit is ignored. Documentation for
this is available under 'help set tunables' in the loader.
- In the case where system memory size can't be accurately determined,
hw.physmem is used as a best-guess memory size, but speculative
probing will be used to determine actual memory size if any of the
guesses or hints are 16M or more.
- If RB_VERBOSE, we list the memory regions as we test them.
- The compile-time option MAXMEM supplies a default value for
'hw.physmem'.
internal services in inetd.conf .
The inetd(8) manpage used to say that the official name of a service
_must_ be used, yet inetd itself was hardcoded to used a service alias for
the auth service, namely ident!
Rather than change inetd.conf and break existing configurations on next
upgrade, we now allow service aliases as well as official names. This
allows the software to work as expected and still support existing
configurations.
This should not breaking existing wrapped configurations either and the
inetd(8) manpage already states that it is the service name specified in
inetd.conf that is used for calls to hosts_access(3).
PR: 11796
Reported by: Alex Charalabidis <alex@wnm.net>
Approved by: des
to bypass the create command.
vinum_stop:
Allow -f option.
Add commands for simplified configuration:
concat - create a volume with one concatenated plex
stripe - create a volume with one striped plex
mirror - create a volume with two concatenated or striped plexes
Egged-on-by: jkh
one hat.
Add -n option for specifying names of volumes created with the
simplified commands.
Add function find_drive_by_devname to help the simplified
configuration commands.
loop it was supposed to be in. Correct some ugly formatting. Remember to
initialize the alignment tag. Honor and pass a callers request to contigalloc
if they had a non-zero alignment constraint.