safe in some cases to reduce CCB priority after it was scheduled with high
priority. This fixes reproducible deadlock when command sent through the
pass interface while ATA XPT recovers from command timeout.
Instead of that enforce priority at passioctl(). libcam provides no obvious
interface to specify CCB priority and so much (all?) code specifies zero
(highest) priority. This change limits pass CCBs priority to NORMAL run
level, allowing XPT to complete bus and device recovery after reset before
running any payload.
on checksums directly from mbuf flags. This simplifies code.
o Clear CSUM_IP from the mbuf in ip_fragment() if we did checksums in
hardware. Some driver may not announce CSUM_IP in theur if_hwassist,
although try to do checksums if CSUM_IP set on mbuf. Example is em(4).
o While here, consistently use CSUM_IP instead of its alias CSUM_DELAY_IP.
After this change CSUM_DELAY_IP vanishes from the stack.
Submitted by: Sebastian Kuzminsky <seb lineratesystems.com>
files. It used to be in files.mips before the clean-room rewrite and
really doesn't belong there. If we need to grow arch specific code,
we can move it into $ARCH/$ACH/siba_machdep.c.
There are some people who use the -HEAD net80211 and wireless drivers
on earlier FreeBSD versions in order to get the updated 802.11n support.
The previous if_clone API changes broke this.
net80211 devices and vaps.
* vnet sets vnet0 during kldload and device probe/attach, but not for
the hotplug event. Thus, plugging in a NIC causes things to panic.
So, add a CURVNET_SET(vnet0) for now during the attach phase, until
the hotplug code is taught to set CURVNET_SET(vnet0).
* there's also no implied detach vnet context - so teach the detach
path about ifp->if_vnet.
* When creating/deleting vaps, also set the vnet context appropriately.
These can be done at any time.
Now, the problems!
* ieee80211.c is supposed to be OS-portable code, with no OS-specific stuff
like vnet. That should be fixed.
* When the device hotplug code gets taught about CURVNET_SET(vnet0), the
device vnet set can go away; but the VAP vnet set still needs to be there.
* .. and there still is the question about potentially adding an implied
CURVNET_SET(ifp->if_vnet) on if_free(), since any/all devices may end up
being detached by a hotplug event in today's world. That's going to be
a topic of a subsequent commit.
command execution. In case of such unhandled exception, vmReset() inside
ficlExecC() flushes the VM state. Attempt to return back to Forth after
that cause garbage dereference with unexpected results. To avoid that
situation call vmThrow() directly instead of expecting Forth to do it.
fragment rate lookups correctly, add a comment describing exactly that.
The assumption in the fragment duration code is the duration of the next
fragment will match the rate used by the current fragment. But I think
a rate lookup is being done for _each_ fragment. For older pre-sample
rate control this would almost always be the case, but for sample
it may be incorrect more often then correct.
POOL_STATE_SPARE and POOL_STATE_L2CACHE were not handled correctly
and thus the cache and spare disks would not be correctly probed.
Reported by: Michael Schmiedgen <schmiedgen@gmx.net>,
Matthew D. Fuller <fullermd@over-yonder.net>
Tested by: Michael Schmiedgen <schmiedgen@gmx.net>,
flo
MFC after: 5 days
advantages. First, PV entries are roughly half the size. Second, this
allocator doesn't access the paging queues, and thus it allows for the
removal of the page queues lock from this pmap.
Replace all uses of the page queues lock by a R/W lock that is private
to this pmap.
Tested by: marcel