The lock order reversal and a resulting deadlock were introduced
in r285021 / D2865. The problem is that zfs_register_callbacks() calls
dsl_prop_get_integer() that has to acquire spa_namespace_lock.
At the same time, spa_config_sync() is called with spa_namespace_lock
held and then it performs ZFS vnode operations that acquire
z_teardown_lock in the reader mode.
So, fix the problem by using dsl_prop_get_int_ds() instead of
dsl_prop_get_integer(). The former does not need to look up
the pool and the dataset by name.
Reported by: many
Reviewed by: delphij
Tested by: delphij, Jens Schweikhardt <schweikh@schweikhardt.net>
MFC after: 5 days
X-MFC with: r285021
Readd the function to create the parents home directory if it does not exists.
if it is only a directory at the top level of the hierarchy symlink it into /usr
as it used to be done before.
Reported by: kevlo, adrian
When updating the row number when the cursor position escape sequence is
issued, we should make sure to store the intermediate result in a 32-bit
integer. If we fail to do this, the cursor may be set above the origin
region, which is bad.
This could cause libteken to crash when INVARIANTS is enabled, due to
the strict set of assertions that libteken has.
PR: 202540
Reported by: kcwu csie org
MFC after: 1 month
* Since r257190 the kernel must actually be loaded at a 64MB boundary, not 16MB.
* Don't program HID1 register on e500mc or e5500, they don't have this SPR.
* Set proper HID0 defaults for these new architectures.
There is still more work to be done for the various SoCs, and the PMAP code
still needs to be extended to 36-bit paddr, coming soon.
Obtained from: Semihalf
Sponsored by: Alex Perez/Inertial Computing
Rather than special casing on PCIC_BRIDGE || PCIC_PROCESSOR, allow all
HDRTYPE_BRIDGE types.
Obtained from: Semihalf
Sponsored by: Alex Perez/Intertial Computing
having some children, the children' reaper is not reset to the parent.
This allows for the situation where reaper has children but not
descendands and the too strict asserts in the reap_status() fire.
Remove the wrong asserts, add some clarification for the situation to
the procctl(2) REAP_STATUS.
Reported and tested by: feld
Sponsored by: The FreeBSD Foundation
MFC after: 1 week
The negative value was not expected and generated the low 8 bits as a byte,
which may be an invalid character encoding.
The final shift in creating the negative value was undefined as well.
Make the temporary variable unsigned to fix this.
Currently vm_pageout_scan() uses a ticks-based scheme to rate-limit
the number of times that the vm_lowmem event will happen. However
if no events happen for long enough for ticks to roll over, this
leaves us in a long window in which vm_lowmem events will not
happen.
Replace the use of ticks with time_t to prevent rollover from ever
being an issue.
Reviewed by: ian
MFC after: 3 weeks
Sponsored by: EMC / Isilon Storage Division
Differential Revision: https://reviews.freebsd.org/D3439
operations always had to be aligned and sized to cache lines. On armv6
and later, cache maintenance operates on a cache line if any part of
the line is referenced in the operation, so we don't need extra code to
align the edges of the sync range.
The significant changes and bugs fixed here are:
1. Fixed a bug in the progress display code:
When the user's filename is too big, or his terminal width is too
small, the progress code could wind up using a negative number for
the length of the "stars" that it uses to indicate progress.
This negative value was assigned to an unsigned variable, resulting
in a very large positive value.
The result is that we wound up writing garbage from memory to the
user's terminal.
With an 80 column terminal, a file name length of more than 35
characters would generate this problem.
To address this, we now set a minimum progress bar length, and
truncate the user's file name as needed.
This has been tested with large filenames and small terminals, and
at least produces reasonable results. If the terminal is too
narrow, the progress display takes up an additional line with each
update, but this is more user friendly than writing garbage to the
tty.
2. SATA drives connected via a SATA controller didn't have SCSI Inquiry
data populated in struct cam_device. This meant that the code in
fw_get_vendor() in fwdownload.c would try to match a zero-length
vendor ID, and so return the first entry in the vendor table. (Which
used to be HITACHI.) Fixed by grabbing identify data, passing the
identify buffer into fw_get_vendor(), and matching against the model
name.
3. SATA drives connected via a SAS controller do have Inquiry data
populated. The table included a couple of entries -- "ATA ST" and
"ATA HDS", intended to handle Seagate and Hitachi SATA drives attached
via a SAS controller. SCSI to ATA translation layers use a vendor
ID of "ATA" (which is standard), and then the model name from the ATA
identify data as the SCSI product name when they are returning data on
SATA disks. The cam_strmatch code will match the first part of the
string (because the length it is given is the length of the vendor,
"ATA"), and return 0 (i.e. a match). So all SATA drives attached to
a SAS controller would be programmed using the Seagate method
(WRITE BUFFER mode 7) of SCSI firmware downloading.
4. Issue #2 above covered up a bug in fw_download_img() -- if the
maximum packet size in the vendor table was 0, it tried to default
to a packet size of 32K. But then it didn't actually succeed in
doing that, because it set the packet size to the value that was
in the vendor table (0). Now that we actually have ATA attached
drives fall use the VENDOR_ATA case, we need a reasonable default
packet size. So this is fixed to properly set the default packet size.
5. Add support for downloading firmware to IBM LTO drives, and add a
firmware file validation method to make sure that the firmware
file matches the drive type. IBM tape drives include a Load ID and
RU name in their vendor-specific VPD page 0x3. Those should match
the IDs in the header of the firmware file to insure that the
proper firmware file is loaded.
6. This also adds a new -q option to the camcontrol fwdownload
subcommand to suppress informational output. When -q is used in
combination with -y, the firmware upgrade will happen without
prompting and without output except if an error condition occurs.
7. Re-add support for printing out SCSI inquiry information when
asking the user to confirm that they want to download firmware, and
add printing of ATA Identify data if it is a SATA disk. This was
removed in r237281 when support for flashing ATA disks was added.
8. Add a new camcontrol(8) "opcodes" subcommand, and use the
underlying code to get recommended timeout values for drive
firmware downloads.
Many SCSI devices support the REPORT SUPPORTED OPERATION CODES
command, and some support the optional timeout descriptor that
specifies nominal and recommended timeouts for the commands
supported by the device.
The new camcontrol opcodes subcommand allows displaying all
opcodes supported by a drive, information about which fields
in a SCSI CDB are actually used by a given SCSI device, and the
nominal and recommended timeout values for each command.
Since firmware downloads can take a long time in some devices, and
the time varies greatly between different types of devices, take
advantage of the infrastructure used by the camcontrol opcodes
subcommand to determine the best timeout to use for the WRITE
BUFFER command in SCSI device firmware downloads.
If the device recommends a timeout, it is likely to be more
accurate than the default 50 second timeout used by the firmware
download code. If the user specifies a timeout, it will override
the default or device recommended timeout. If the device doesn't
support timeout descriptors, we fall back to the default.
9. Instead of downloading firmware to SATA drives behind a SAS controller
using WRITE BUFFER, use the SCSI ATA PASS-THROUGH command to compose
an ATA DOWNLOAD MICROCODE command and it to the drive. The previous
version of this code attempted to send a SCSI WRITE BUFFER command to
SATA drives behind a SAS controller. Although that is part of the
SAT-3 spec, it doesn't work with the parameters used with LSI
controllers at least.
10.Add a new mechanism for making common ATA passthrough and
ATA-behind-SCSI passthrough commands.
The existing camcontrol(8) ATA command mechanism checks the device
type on every command executed. That works fine for individual
commands, but is cumbersome for things like a firmware download
that send a number of commands.
The fwdownload code detects the device type up front, and then
sends the appropriate commands.
11.In simulation mode (-s), if the user specifies the -v flag, print out
the SCSI CDB or ATA registers that would be sent to the drive. This will
aid in debugging any firmware download issues.
sbin/camcontrol/fwdownload.c:
Add a device type to the fw_vendor structure, so that we can
specify different download methods for different devices from the
same vendor. In this case, IBM hard drives (from when they
still made hard drives) and tape drives.
Add a tur_status field to the fw_vendor structure so that we can
specify whether the drive to be upgraded should be ready, not
ready, or whether it doesn't matter. Add the corresponding
capability in fw_download_img().
Add comments describing each of the vendor table fields.
Add HGST and SmrtStor to the supported SCSI vendors list.
In fw_get_vendor(), look at ATA identify data if we have a SATA
device to try to identify what the drive vendor is.
Add IBM firmware file validation. This gets VPD page 0x3, and
compares the Load ID and RU name in the page to the values
included in the header. The validation code will refuse to load
a firmware file if the values don't match. This does allow the
user to attempt a downgrade; whether or not it succeeds will
likely depend on the drive settings.
Add a -q option, and disable all informative output
(progress bars, etc.) when this is enabled.
Re-add the inquiry in the confirmation dialog so the user has
a better idea of which device he is talking to. Add support for
displaying ATA identify data.
Don't automatically disable confirmation in simulation (-s) mode.
This allows the user to see the inquiry or identify data in the
dialog, and see exactly what they would see when the command
actually runs. Also, in simulation mode, if the user specifies
the -v flag, print out the SCSI CDB or ATA registers that would
be sent to the drive. This will aid in debugging any firmware
download issues.
Add a timeout field and timeout type to the firmware download
vendor table. This allows specifying a default timeout and allows
specifying whether we should attempt to probe for a recommended
timeout from the drive.
Add a new fuction, fw_get_timeout(), that will determine
which timeout to use for the WRITE BUFFER command. If the
user specifies a timeout, we always use that. Otherwise,
we will use the drive recommended timeout, if available,
and fall back to the default when a drive recommended
timeout isn't available.
When we prompt the user, tell him what timeout we're going
to use, and the source of the timeout.
Revamp the way SATA devices are handled.
In fwdownload(), use the new get_device_type() function to
determine what kind of device we're talking to.
Allow firmware downloads to any SATA device, but restrict
SCSI downloads to known devices. (The latter is not a
change in behavior.)
Break out the "ready" check from fw_download_img() into a
new subfunction, fw_check_device_ready(). This sends the
appropriate command to the device in question -- a TEST
UNIT READY or an IDENTIFY. The IDENTIFY for SATA devices
a SAT layer is done using the SCSI ATA PASS-THROUGH
command.
Use the new build_ata_cmd() function to build either a SCSI or
ATA I/O CCB to issue the DOWNLOAD MICROCODE command to SATA
devices. build_ata_cmd() figures looks at the devtype argument
and fills in the correct CCB type and CDB or ATA registers.
Revamp the vendor table to remove the previous
vendor-specific ATA entries and use a generic ATA vendor
placeholder. We currently use the same method for all ATA
drives, although we may have to add vendor-specific
behavior once we test this with more drives.
sbin/camcontrol/progress.c:
In progress_draw(), make barlength a signed value so that
we can easily detect a negative value.
If barlength (the length of the progress bar) would wind up
negative due to a small TTY width or a large filename,
set the bar length to the new minimum (10 stars) and
truncate the user's filename. We will truncate it down to
0 characters if necessary.
Calculate a new prefix_len variable (user's filename length)
and use it as the precision when printing the filename.
sbin/camcontrol/camcontrol.c:
Implement a new camcontrol(8) subcommand, "opcodes". The
opcodes subcommand allows displaying the entire list of
SCSI commands supported by a device, or details on an
individual command. In either case, it can display
nominal and recommended timeout values.
Add the scsiopcodes() function, which calls the new
scsigetopcodes() function to fetch opcode data from a
drive.
Add two new functions, scsiprintoneopcode() and
scsiprintopcodes(), which print information about one
opcode or all opcodes, respectively.
Remove the get_disk_type() function. It is no longer used.
Add a new function, dev_has_vpd_page(), that fetches the
supported INQUIRY VPD list from a device and tells the
caller whether the requested VPD page is available.
Add a new function, get_device_type(), that returns a more
precise device type than the old get_disk_type() function.
The get_disk_type() function only distinguished between
SCSI and ATA devices, and SATA devices behind a SCSI to ATA
translation layer were considered to be "SCSI".
get_device_type() offers a third type, CC_DT_ATA_BEHIND_SCSI.
We need to know this to know whether to attempt to send ATA
passthrough commands. If the device has the ATA
Information VPD page (0x89), then it is an ATA device
behind a SCSI to ATA translation layer.
Remove the type argument from the fwdownload() subcommand.
Add a new function, build_ata_cmd(), that will take one set
of common arguments and build either a SCSI or ATA I/O CCB,
depending on the device type passed in.
sbin/camcontrol/camcontrol.h:
Add a prototype for scsigetopcodes().
Add a new enumeration, camcontrol_devtype.
Add prototypes for dev_has_vpd_page(), get_device_type()
and build_ata_cmd().
Remove the type argument from the fwdownload() subcommand.
sbin/camcontrol/camcontrol.8
Explain that the fwdownload subcommand will use the drive
recommended timeout if available, and that the user can
override the timeout.
Document the new opcodes subcommand.
Explain that we will attempt to download firmware to any
SATA device.
Document supported SCSI vendors, and models tested if known.
Explain the commands used to download firmware for the
three different drive and controller combinations.
Document that the -v flag in simulation mode for the fwdownload
subcommand will print out the SCSI CDBs or ATA registers that would
be used.
sys/cam/scsi/scsi_all.h:
Add new bit definitions for the one opcode descriptor for
the REPORT SUPPORTED OPCODES command.
Add a function prototype for scsi_report_supported_opcodes().
sys/cam/scsi/scsi_all.c:
Add a new CDB building function, scsi_report_supported_opcodes().
Sponsored by: Spectra Logic
MFC after: 1 week
arrays generically rather than duplicating a hack in all of the backends.
- Add two new system call argument types and use them instead of StringArray
for the argument and environment arguments execve and linux_execve.
- Honor the -a/-e flags in the handling of these new types.
- Instead of printing "<missing argument>" when the decoding is disabled,
print the raw pointer value.
Before truss would fetch 100 string pointers and happily walk off the end
of the array if it never found a NULL. This also means for a short argv
list it could fail entirely if the 100 string pointers spanned into an
unmapped page.
Instead, fetch page-aligned blocks of string pointers in a loop fetching
each string until a NULL is found.
While here, make use of the open memstream file descriptor instead of
allocating a temporary array. This allows us to fetch each string once
instead of twice.
Before that, the logic besides lle_create() was the following:
return existing if found, create if not. This behaviour was error-prone
since we had to deal with 'sudden' static<>dynamic lle changes.
This commit fixes bunch of different issues like:
- refcount leak when lle is converted to static.
Simple check case:
console 1:
while true;
do for i in `arp -an|awk '$4~/incomp/{print$2}'|tr -d '()'`;
do arp -s $i 00:22:44:66:88:00 ; arp -d $i;
done;
done
console 2:
ping -f any-dead-host-in-L2
console 3:
# watch for memory consumption:
vmstat -m | awk '$1~/lltable/{print$2}'
- possible problems in arptimer() / nd6_timer() when dropping/reacquiring
lock.
New logic explicitly handles use-or-create cases in every lla_create
user. Basically, most of the changes are purely mechanical. However,
we explicitly avoid using existing lle's for interface/static LLE records.
* While here, call lle_event handlers on all real table lle change.
* Create lltable_free_entry() calling existing per-lltable
lle_free_t callback for entry deletion
missing until it can be cleaned up.
Reviewed by: jhb
Approved by: ABT Systems Ltd
Sponsored by: The FreeBSD Foundation
Differential Revision: https://reviews.freebsd.org/D3319
Watchdogd currently disables the watchdog when it exits, such as during
rc.shutdown processing. That leaves the system vulnerable to getting hung
or deadlocked during the shutdown part of a reboot. For embedded systems
it's especially important that the hardware watchdog always be active. It
can also be useful for servers that are administered remotely.
The new -x <seconds> option tells watchdogd to program the watchdog with the
given timeout just before exiting. The -x value can be longer or shorter
than the -t normal time value, to allow for various exceptional conditions
at shutdown such as allowing extra time for buffer flushing.
The exit value is also used internally in the "failsafe" handling (which
used to just disable the watchdog), on the theory that if you're using this
option, "safe" means having the watchdog always running, not disabled.
The default is still to disable the watchdog on exit if -x is not specified.
Differential Revision: https://reviews.freebsd.org/D2556 (timed out)
I introduced a local copy of __multc3 in r281221, which has now been
committed upstream to compiler-rt in revision 245296. Update our version
to match the changes made there.
Sponsored by: The FreeBSD Foundation
Also, follow the rules from watchdog(9) about what values to return in
various situations (especially, don't touch *error when asked to set a
non-zero timeout that isn't achievable on the hardware).
Also, move the READ/WRITE bus space access macros from the header into the
source file, and rename them to RD2/WR2 to make it clear they're 16-bit
accessors. (READ/WRITE just don't seem like good names to be in a public
header file.)
Distinguish between WRDE_BADVAL and WRDE_SYNTAX based on when the error
occurred (parsing or execution), not based on whether WRDE_UNDEF was passed.
Also, return WRDE_NOSPACE for a few more unexpected results from sh.